Trace Oxygen Analyzer

Introduction

 

 

 

Introduction

1.1 Overview

The Teledyne Electronic Technologies Analytical Instruments

(TETAI) Model 3190Z is a microprocessor-based trace oxygen analyzer for real-time measurement of trace amounts of oxygen in inert gases, or in a wide variety of gas mixtures. It features simple operation, fast response, and a compact, rugged construction.

1.2 Main Features of the Analyzer

The main features of the analyzer include:

High resolution, accurate readings of oxygen content from 0-10 parts per million (ppm) through 0-1,000 ppm. Large, bright, light-emitting-diode meter readout

Simple pushbutton controls

Advanced Zirconium Oxide measuring technology sensors

Fast response and recovery time

Microprocessor based electronics: 8-bit CMOS with on-board RAM and 16 KB ROM

Two user selectable ranges (depending on sensor configuration) allow best match to user’s process and equipment

Operator can select auto-ranging, allowing the analyzer to automatically select the proper preset range for a given measurement or lock the analyzer onto a single range

Two concentration alarms with adjustable set-points

Three analog outputs: two for measurement (0–10 VDC and negative ground 4–20 mADC) and one for range identification (0-10 VDC).

Teledyne Analytical Instruments

1

Image 9
Contents Teledyne Analytical Instruments Trace Oxygen AnalyzerCopyright 2009 Teledyne Instruments/ Analytical Instruments Model 3190ZSafety Messages Model 3190Z Table of Contents Maintenance Combustible GAS Usage Viii Introduction Main Features of the AnalyzerOverview Trace Oxygen Analyzer IntroductionFront Panel Description Introduction Model 3190ZSpan Rear Panel Description Meter ReadoutMeasurement Parameters Readout Rear Panel AC and DC versions ƒ Power ConnectionAlarm Page Introduction Operational TheoryZirconium Oxide Sensors Trace Oxygen Analyzer Operational TheoryOperational Theory Model 3190Z ElectronicsEffect of Pressure GeneralBlock Diagram of the Signal Processing Electronics Signal ProcessingOperational Theory Model 3190Z Installation Trace Oxygen Analyzer InstallationUnpacking the Analyzer Control Unit Installation Installation Model 3190ZExternal Probe Installation Location and MountingPower switch is located below the fuse receptacle Rear Panel Electrical Connectors for AC and DC Units Contact ID for Failsafe Relay Operation Gas Connections Installation ChecklistTrace Oxygen Analyzer Operation OperationUsing the Function and Data Entry Buttons Setting the Analysis RangesOperation Model 3190Z HI Alarm Setting the Alarm SetpointsLO Alarm HI RangeProcedure Sensor Fail AlarmSelecting a Fixed Range or Autoranging CalibrationLED Display on StartUp Page Trace Oxygen Analyzer Maintenance MaintenanceAC Powered Units Replacing the FuseMaintenance Model 3190Z Sensor Installation or ReplacementDC Powered Units When to Replace a SensorAppendix SpecificationsTrace Oxygen Analyzer Appendix Range ID 0-10 VDCAppendix Model 3190Z Spare Parts ListMiscellaneous Drawing List