Panasonic CS-KE36NKU, CU-KE36NKU, CU-KE30NKU 30,900 30,870 30,800 30,710 30,590 30,400 30,210

Page 26

Indoor Unit

: CS-KE36NKU

 

 

 

 

 

 

 

 

 

 

 

Outdoor Unit

: CU-KE36NKU

 

 

 

 

 

 

 

 

 

 

 

Power Supply : 230V Single Phase 60Hz

 

 

 

 

 

 

 

 

 

 

< Cooling Capacity (Low Ambient) >

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATING CAPACITY:

34,000 BTU/h

 

AIR FLOW RATE:

 

630 CFM

 

 

INDOOR

 

 

 

 

OUTDOOR

 

 

 

 

 

ENT. TEMP. oF (oC)

 

 

 

 

AMBIENT TEMP.oF (oC)

 

 

 

 

WB

DB

 

 

0

5

15

 

25

 

35

45

55

 

 

 

 

 

 

(-17.8)

(-15.0)

(-9.4)

 

(-3.9)

 

(1.7)

(7.2)

(12.8)

 

 

 

 

TC

 

30,900

30,870

30,800

 

30,710

 

30,590

30,400

30,210

 

 

 

72 (22.2)

SHC

 

21,510

21,510

21,510

 

23,230

 

21,390

21,270

21,150

 

 

59

76 (24.4)

SHC

 

23,960

23,840

23,840

 

25,550

 

23,710

23,590

23,470

 

 

(15.0)

80 (26.7)

SHC

 

26,400

26,400

26,280

 

27,870

 

26,160

26,040

25,920

 

 

 

84 (28.9)

SHC

 

28,730

28,730

28,610

 

30,200

 

28,480

28,480

28,360

 

 

 

88 (31.1)

SHC

 

30,900

30,870

30,800

 

30,710

 

30,590

30,400

30,210

 

 

 

 

TC

 

31,010

31,010

30,990

 

30,950

 

30,890

30,750

30,620

 

 

 

72 (22.2)

SHC

 

17,970

17,970

17,970

 

23,230

 

17,970

17,840

17,840

 

 

63

76 (24.4)

SHC

 

20,410

20,410

20,290

 

25,550

 

20,290

20,170

20,170

 

 

(17.2)

80 (26.7)

SHC

 

22,860

22,860

22,740

 

27,870

 

22,740

22,610

22,610

 

 

 

84 (28.9)

SHC

 

25,180

25,180

25,180

 

30,200

 

25,060

25,060

24,940

 

 

 

88 (31.1)

SHC

 

27,510

27,510

27,510

 

30,950

 

27,380

27,380

27,260

 

 

 

 

TC

 

30,910

30,940

30,980

 

31,000

 

31,010

30,930

30,880

 

 

 

72 (22.2)

SHC

 

14,420

14,420

14,420

 

23,230

 

14,420

14,420

14,420

 

 

67

76 (24.4)

SHC

 

16,740

16,740

16,740

 

25,550

 

16,740

16,740

16,740

 

 

(19.4)

80 (26.7)

SHC

 

19,190

19,190

19,190

 

27,870

 

19,190

19,190

19,190

 

 

 

84 (28.9)

SHC

 

21,510

21,510

21,640

 

30,200

 

21,640

21,510

21,510

 

 

 

88 (31.1)

SHC

 

23,840

23,960

23,960

 

31,000

 

23,960

23,960

23,840

 

 

 

 

TC

 

30,570

30,620

30,730

 

30,820

 

30,910

30,900

30,930

 

 

 

72 (22.2)

SHC

 

10,630

10,630

10,750

 

23,230

 

10,750

10,750

10,750

 

 

71

76 (24.4)

SHC

 

12,950

12,950

13,070

 

25,550

 

13,070

13,070

13,070

 

 

(21.7)

80 (26.7)

SHC

 

15,400

15,400

15,520

 

27,870

 

15,520

15,520

15,520

 

 

 

84 (28.9)

SHC

 

17,720

17,840

17,840

 

30,200

 

17,970

17,970

17,970

 

 

 

88 (31.1)

SHC

 

20,170

20,170

20,170

 

30,820

 

20,290

20,290

20,290

 

 

 

 

TC

 

30,010

30,090

30,260

 

30,430

 

30,590

30,650

30,770

 

 

75

76 (24.4)

SHC

 

9,410

9,410

9,530

 

25,550

 

9,650

9,650

9,650

 

 

(23.9)

80 (26.7)

SHC

 

11,850

11,850

11,970

 

27,870

 

12,100

12,100

12,100

 

 

 

84 (28.9)

SHC

 

14,180

14,180

14,300

 

30,200

 

14,420

14,420

14,420

 

 

 

88 (31.1)

SHC

 

16,500

16,620

16,620

 

30,430

 

16,740

16,740

16,870

 

 

 

 

TC : Total Cooling Capacity (BTU/h)

SHC : Sensible Heat Capacity (BTU/h)

NOTE

1.Above data does not take Freeze Prevention Protection during cooling operation into account. For this reason, the value may vary from the actual cooling characteristics.

2.Above data represents the value when the operation frequency of a compressor is fixed.

26

Image 26
Contents Outdoor Model No Product Code No CS-KE30NKU + CU-KE30NKU CS-KE36NKU + CU-KE36NKUIndoor Model No Product Code No 852 360Safety Precautions Prohibit Table of Contents Checking Electrical Components Temperature Indoor Air Intake Temp Outdoor Air Intake Temp Operating RangeIndoor Unit SpecificationsUnit Specifications Outdoor Unit208V CS-KE36NKU 21.9 19.9 Indoor Unit CS-KE30NKU Major Component SpecificationsIndoor Unit Indoor Unit CS-KE36NKU CB-CS-KE36NKUBoard Outdoor UnitOutdoor Unit CU-KE30NKU CompressorOutdoor Unit CU-KE36NKU Other Component Specifications Dimensional Data Inchmm 194-00-1 Unit Indoor Unit CS-KE30NKU Outdoor Unit CU-KE30NKU Refrigerant Flow DiagramRefrigerant Flow Diagram Indoor unit Outdoor unitTemperature Charts Performance DataHigh pressure performance chart Indoor Unit CS-KE36NKU Outdoor Unit CU-KE36NKU Discharge 9535 8630 Indoor CS-KE30NKU Power Supply 230V Single Phase 60Hz Cooling CapacityCooling Capacity CU-KE30NKU34,000 BTU/h Cooling Capacity Low Ambient Outdoor30,900 30,870 30,800 30,710 30,590 30,400 30,210 TH Total Heating Capacity BTU/h Power Supply 230V Single Phase 60Hz Heating CapacityHeating Capacity 36,000 BTU/h Air Throw Distance Charts Cooling Voltage230V Cooling Electrical CharacteristicsElectrical Data Heating650 Electric Wiring Diagrams 8FA2-5251-12400-18FA2-5251-15200-0 ControllerEmergency operation FunctionsOperation Functions Auto cooling/heating operationTimer backup Lamp colorsOperation Sound Switching Procedure to Noise Reducing ControlNoise Reducing Control Outdoor Unit Description of function Maximum Current Value Change ProcedureMaximum Current Value Change Function CU-KE36NKUOverload prevention during heating Compressor discharge temperature controlProtective Functions Freeze preventionReverse-Cycle Defrosting Defrost detection and releaseCT Peak current cut-off control Method of Self-Diagnostics Troubleshooting Before Calling for ServicePrecautions before Performing Inspection or Repair Self-diagnostics Lamps Diagnosis ContentsReplace the circuit board or the fuse NormalReplace the controller Checking the indoor unit Control Check items unit operation Using the TEST/T-RUN terminalsChecking the Indoor and Outdoor Units Off Blinking Illuminated Serial Communication Error Identification ProcedureAlarm Code E05 Before the OperationFrom the previous page a Alarm Code E07/P04/P05/P20/P27 Trouble Diagnosis of Fan Motor Indoor Fan MotorPin 1 Vcc brown Outdoor Fan MotorPin 3 Gnd blue Pin 2 PG whiteElectromagnetic interference Noise Malfunction and Electromagnetic InterferenceNoise malfunction Locations most susceptible to noise Trouble CorrectionMeasurement of Insulation Resistance Power Supply CordChecking Electrical Components Measurement of Insulation Resistance for Electrical PartsChecking Continuity of Fuse on PCB Assy What is New Refrigerant R410A? Refrigerant R410A Special Precautions When Servicing UnitCharacteristics of New Refrigerant R410A CharacteristicsChecklist before Servicing Tubing Installation Procedures Tools Specifically for R410AProcedure for Replacing Compressor Case of Compressor MalfunctionExample Configuration and characteristics of cylindersAmount in the charging cylinder is less than 20% To prevent the compositionRecharging Case Refrigerant is LeakingWelding leaking points Retro-Fitting Existing Systems When Tubes are ExtendedCharging Additional Refrigerant Use of Existing UnitsAppendix a Operating Instructions CS-KE30NKU CS-KE36NKUSafety Precautions FeaturesContents Product InformationElectrical Requirements Installation LocationSafety Instructions AvoidNames of Parts Unit Display and Operation ButtonRemote Controller Display SymbolsRemote Controller Mode selector button HR. Timer button 1-HOUR OFF TimerTemperature setting buttons Temp High Power button32 x 13/16 Using the Remote ControllerACL button 20 mmOperation with the Remote Controller Automatic OperationAutomatic fan speed Cooling and DRY ModeHeating Mode Manual fan speedHigh Power Mode Unoccupied Indication StatusSpecial Remarks Setting the Timer Operation Indication1030 pm 710 am 1100 am Present time Using the 1-HOUR OFF TimerTips for Energy Saving Adjusting the Airflow Direction When the air conditioner is not runningRemoving and remounting the front panel How to replace the filterCleaning the main unit and Remote Controller Washing the front panel with waterTrouble Possible Cause Remedy Wired Remote ControllerOperating Range Specifications Model No Outdoor Unit Indoor UnitPage 852-6-4190-587-00-0 Installation Instructions Split System Air Conditioner ContentsPlease Read Before Starting Fins of the outdoor unit. You may get injured AccidentallyGeneral Tools Required for Installation not suppliedAccessories Supplied with Unit Table Optional Copper Tubing KitInstallation Site Selection Additional Materials Required for InstallationSolid base must not cover the hole of the bottom plate  $/,8,3?,4508-25=  $/,04.3?-8,,D,4+89 Precautions for Installation in a Snowy Area Countermeasures against snow and wind Unit inch $/,-8544+5/90+,9398,30456,4 Required space around the outdoor unit4922054=0/041,9-*04.52,9 27-5/8 11-5/8 Air Intake 25/32 13/32 13-3/8 14-31/32 4522,8/4/,/,0./5-/,5+55840  #04.2,4004922054  9*2,9545/90+,9 #04.2,4004922054 Installation in front-rear rowsObstacles to the front and rear of unit  9*2,9545/90+,9Remove the Rear Panel from the Unit How to Install the Indoor UnitTrical wiring or conduits are Make a HoleIf Block, Brick, Concrete or Similar Type Wall Install the Rear Panel on the WallIf Wooden Wall Hole DiaHow to replace the grille Removing and Installing the GrilleHow to remove the grille Wiring Instructions General precautions on wiring Shape the Indoor Side TubingWire Size and Length Wiring Instructions for Inter-unit Connections  For stranded wiring How to connect wiring to the terminal For Indoor UnitFor Outdoor Unit  For solid core wiring or F-cable Mounting  Right-side tubingDrain cap Switching drain hose and drain cap Left-side tubing To unmount indoor unit Do not supply power toTubing and wiring to the out Frame Fastening MethodRouting the Tubing and Wiring How to Install the Outdoor UnitWiring Instructions for the Outdoor Unit Cover BRefrigerant Tubing Flaring Procedure with a Flare ToolTo 0.5 mm Adjust so that the amount of tube Use of the Flaring MethodInsulation of Refrigerant Tubing Connecting Tubing between Indoor and Outdoor UnitsFinishing the Installation Taping the TubesAir Purging Attempting to turn the valve Be sure to completely insertHex wrench before How to Test Run the Air Conditioner  Basic Functions of the Service Valves  Pump Down Service Valve Connections Remote Controller Installation PositionAddress Switch Address Setting of the Remote ControllerDC1111-0

CS-KE30NKU, CS-KE36NKU, CU-KE30NKU, CU-KE36NKU specifications

The Panasonic CU-KE36NKU, CS-KE36NKU, CU-KE30NKU, and CS-KE30NKU air conditioning units represent the brand's commitment to delivering high-performance cooling solutions backed by innovative technologies. These units cater to both residential and commercial applications, ensuring users experience maximum comfort throughout the year.

One of the standout features of these models is their energy efficiency. Both units are equipped with advanced inverter technology, which allows for variable speed operation. This means they can adjust their power output according to the room's cooling needs, reducing energy consumption and minimizing electric bills while maintaining a consistent temperature. The models boast impressive SEER (Seasonal Energy Efficiency Ratio) ratings, making them environmentally friendly options.

Panasonic's nanoe-G technology is another remarkable feature incorporated into these models. This technology helps to purify the air by generating hydroxyl radicals, which eliminate airborne particles, odors, and harmful bacteria. This results in a healthier indoor environment, conducive to both comfort and well-being. The air purification aspect not only enhances the air quality but also extends the lifespan of the HVAC system by reducing the buildup of dust and contaminants.

In terms of user convenience, both the CU-KE and CS-KE series are equipped with programmable timers, allowing users to set their desired operation schedules. They also come with a remote control for ease of use, enabling adjustments from a distance. The installation process is straightforward, and the sleek design blends seamlessly with various interior aesthetics, making them a suitable choice for any room.

Durability is a key characteristic of Panasonic air conditioning units, and the CU-KE36NKU, CS-KE36NKU, CU-KE30NKU, and CS-KE30NKU are designed to withstand varying environmental conditions. Their robust construction ensures reliability and performance over the years. Additionally, both models come with a quiet operation feature that minimizes noise levels, allowing for comfortable use without disturbing daily activities.

In summary, the Panasonic CU-KE36NKU, CS-KE36NKU, CU-KE30NKU, and CS-KE30NKU are exceptional air conditioning units that combine energy efficiency, innovative purification technology, user-friendly features, and robust durability. These models are an ideal investment for anyone seeking a reliable and high-performance cooling solution.