Panasonic CS-KE30NKU, CU-KE36NKU Unit Specifications, Indoor Unit, Outdoor Unit, 230V

Page 7

2. SPECIFICATIONS

2-1. Unit Specifications

Indoor Unit

CS-KE30NKU

 

 

 

 

 

 

 

Outdoor Unit

CU-KE30NKU

 

 

 

 

 

 

< 230V >

 

 

 

 

 

 

 

 

 

 

 

Voltage Rating

 

 

 

 

 

 

230V Single-Phase 60Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

 

Heating

Performance

 

 

 

 

 

 

 

 

 

 

Total Capacity

 

 

 

 

BTU/h

30,600

( 10,900 to 30,600 )

33,000

( 14,000 to 33,000 )

 

 

 

 

 

 

kW

9.0

( 3.2 to 9.0 )

9.7

( 4.1 to 9.7 )

Sensible Capacity

 

 

 

 

BTU/h

 

18,600

 

-

Latent Capacity

 

 

 

 

BTU/h

 

12,000

 

-

Air Circulation (Hi/Me/Lo)

ft3/min (m3/h)

630(1,070)/530(901)/412(700)

671(1,140)/559(950)/441(749)

 

Moisture Removal (High)

 

 

Pints/h

 

9.57

 

-

 

Available Voltage Range

 

 

V

 

187 to 253

 

 

Running Amperes

 

 

 

 

A

16.5

( 5.0 to 16.5 )

15.3

( 4.5 to 15.3 )

Rating

Power Input

 

 

 

 

 

W

3,290

( 1,000 to 3,290 )

3,070

( 900 to 3,070 )

Power Factor

 

 

 

 

%

 

87

 

87

EER

 

 

 

 

 

BTU/h/W

 

9.30

 

-

Electrical

 

 

 

 

 

 

 

COP

 

 

 

 

 

W/W

 

-

 

3.15

SEER

 

 

 

 

 

BTU/Wh

 

16.0

 

-

HSPF

 

 

 

 

 

BTU/Wh

 

-

 

9.0

 

Compressor Locked Rotor Amperes

 

 

A

 

31.0

 

 

Fuse or Circuit Breaker Capacity

 

 

A

 

35

 

 

Controls / Temperature Control

 

 

 

 

Microprocessor / I.C. Thermister

 

Control Unit

 

 

 

 

 

 

 

Wireless Remote Control Unit

 

Timer

 

 

 

 

 

 

 

24-Hour ON or OFF Timer, 1-Hour OFF Timer

 

Fan Speeds

 

 

Indoor / Outdoor

 

Auto and 3 steps / Auto (Hi, Me, Lo)

 

Airflow Direction (Indoor)

 

 

Horizontal

 

Manual

 

 

 

 

 

 

 

 

Vertical

 

Auto

 

Features

Air Filter

 

 

 

 

 

 

 

Washable, Anti-Mold

Compressor

 

 

 

 

 

 

 

DC Twin Rotary (Inverter)

Refrigerant / Amount charged at shipment

 

 

Ibs (g)

 

R410A / 6.5 (2,950)

Refrigerant Control

 

 

 

 

 

 

Electric Expansion Valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation Sound

 

Indoor : Hi/Me/Lo/Qt*

dB-A

49 / 44 / 39 / 32

49 / 44 / 39 / 32

 

(*Qt = Quiet mode)

 

Outdoor : Hi

 

 

dB-A

 

55

 

55

 

Refrigerant Tubing Connections

 

 

 

 

Flare Type

 

 

Max. allowable tubing length at shipment

 

 

ft (m)

 

164 (50)

 

 

Refrigerant

 

 

Narrow tube

 

 

inch (mm)

 

3/8 (9.52)

 

 

Tube Diameter

 

Wide tube

 

 

inch (mm)

 

5/8 (15.88)

 

 

Refrigerant Tube Kit

 

 

 

 

 

 

Optional

 

Weight

 

 

 

 

 

 

 

 

Indoor Unit

 

Outdoor Unit

Unit Dimensions

 

 

 

 

inch

11-13/16 σ 41-15/16 σ 9-1/16

35-13/16 σ 37-1/32 σ 13-3/8

Height σ Width

σ Depth

 

 

(mm)

(300 σ 1,065 σ 230)

(910 σ 940 σ 340)

&

 

 

Package Dimensions

 

 

inch

12-7/32 σ 44-7/8 σ 14-31/32

42-3/8 σ 40 σ 16-3/8

Dimensions

 

 

Height σ Width σ Depth

 

 

(mm)

(310 σ 1,140 σ 380)

(1,076 σ 1,016 σ 416)

Weight

 

 

Net

 

 

Ibs (kg)

 

32.0 (14.5)

 

185.2 (84.0)

 

 

 

Shipping

 

 

Ibs (kg)

 

39.7 (18.0)

 

207.2 (94.0)

Shipping Volume

 

 

 

 

cu.ft (m3)

 

4.59 (0.13)

 

15.88 (0.45)

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

Remarks: Rating conditions are:

 

 

 

 

Cooling: Indoor air temperature

80 °F DB / 67 °F WB

Heating: Indoor air temperature

70

°F DB

Outdoor air temperature

95 °F DB / 75 °F WB

Outdoor air temperature

47

°F DB / 43 °F WB

7

Image 7
Contents 852 360 CS-KE30NKU + CU-KE30NKU CS-KE36NKU + CU-KE36NKUIndoor Model No Product Code No Outdoor Model No Product Code NoSafety Precautions Prohibit Table of Contents Checking Electrical Components Operating Range Temperature Indoor Air Intake Temp Outdoor Air Intake TempOutdoor Unit SpecificationsUnit Specifications Indoor Unit208V CS-KE36NKU 21.9 19.9 Indoor Unit Major Component SpecificationsIndoor Unit CS-KE30NKU CB-CS-KE36NKU Indoor Unit CS-KE36NKUCompressor Outdoor UnitOutdoor Unit CU-KE30NKU BoardOutdoor Unit CU-KE36NKU Other Component Specifications Dimensional Data Inchmm 194-00-1 Unit Indoor unit Outdoor unit Refrigerant Flow DiagramRefrigerant Flow Diagram Indoor Unit CS-KE30NKU Outdoor Unit CU-KE30NKUPerformance Data Temperature ChartsHigh pressure performance chart Indoor Unit CS-KE36NKU Outdoor Unit CU-KE36NKU Discharge 9535 8630 Indoor CU-KE30NKU Power Supply 230V Single Phase 60Hz Cooling CapacityCooling Capacity CS-KE30NKU34,000 BTU/h Outdoor Cooling Capacity Low Ambient30,900 30,870 30,800 30,710 30,590 30,400 30,210 Heating Capacity Power Supply 230V Single Phase 60Hz Heating CapacityTH Total Heating Capacity BTU/h 36,000 BTU/h Air Throw Distance Charts Cooling Heating Electrical CharacteristicsElectrical Data Voltage230V Cooling650 8FA2-5251-12400-1 Electric Wiring DiagramsController 8FA2-5251-15200-0Auto cooling/heating operation FunctionsOperation Functions Emergency operationLamp colors Timer backupNoise Reducing Control Outdoor Unit Switching Procedure to Noise Reducing ControlOperation Sound CU-KE36NKU Maximum Current Value Change ProcedureMaximum Current Value Change Function Description of functionFreeze prevention Compressor discharge temperature controlProtective Functions Overload prevention during heatingCT Peak current cut-off control Defrost detection and releaseReverse-Cycle Defrosting Precautions before Performing Inspection or Repair Troubleshooting Before Calling for ServiceMethod of Self-Diagnostics Diagnosis Contents Self-diagnostics LampsReplace the controller NormalReplace the circuit board or the fuse Checking the Indoor and Outdoor Units Using the TEST/T-RUN terminalsChecking the indoor unit Control Check items unit operation Before the Operation Serial Communication Error Identification ProcedureAlarm Code E05 Off Blinking IlluminatedFrom the previous page a Alarm Code E07/P04/P05/P20/P27 Indoor Fan Motor Trouble Diagnosis of Fan MotorPin 2 PG white Outdoor Fan MotorPin 3 Gnd blue Pin 1 Vcc brownLocations most susceptible to noise Trouble Correction Noise Malfunction and Electromagnetic InterferenceNoise malfunction Electromagnetic interferenceMeasurement of Insulation Resistance for Electrical Parts Power Supply CordChecking Electrical Components Measurement of Insulation ResistanceChecking Continuity of Fuse on PCB Assy Characteristics Refrigerant R410A Special Precautions When Servicing UnitCharacteristics of New Refrigerant R410A What is New Refrigerant R410A?Checklist before Servicing Tools Specifically for R410A Tubing Installation ProceduresCase of Compressor Malfunction Procedure for Replacing CompressorTo prevent the composition Configuration and characteristics of cylindersAmount in the charging cylinder is less than 20% ExampleWelding leaking points Case Refrigerant is LeakingRecharging Use of Existing Units When Tubes are ExtendedCharging Additional Refrigerant Retro-Fitting Existing SystemsAppendix a Operating Instructions CS-KE36NKU CS-KE30NKUProduct Information FeaturesContents Safety PrecautionsAvoid Installation LocationSafety Instructions Electrical RequirementsUnit Display and Operation Button Names of PartsSymbols Remote Controller DisplayRemote Controller High Power button HR. Timer button 1-HOUR OFF TimerTemperature setting buttons Temp Mode selector button20 mm Using the Remote ControllerACL button 32 x 13/16Automatic Operation Operation with the Remote ControllerManual fan speed Cooling and DRY ModeHeating Mode Automatic fan speedUnoccupied Indication Status High Power ModeSpecial Remarks Operation Indication Setting the TimerTips for Energy Saving Using the 1-HOUR OFF Timer1030 pm 710 am 1100 am Present time When the air conditioner is not running Adjusting the Airflow DirectionWashing the front panel with water How to replace the filterCleaning the main unit and Remote Controller Removing and remounting the front panelOperating Range Wired Remote ControllerTrouble Possible Cause Remedy Model No Outdoor Unit Indoor Unit SpecificationsPage 852-6-4190-587-00-0 Contents Installation Instructions Split System Air ConditionerPlease Read Before Starting Accidentally Fins of the outdoor unit. You may get injuredOptional Copper Tubing Kit Tools Required for Installation not suppliedAccessories Supplied with Unit Table GeneralAdditional Materials Required for Installation Installation Site SelectionSolid base must not cover the hole of the bottom plate  Countermeasures against snow and wind Precautions for Installation in a Snowy Area $/,8,3?,4508-25=  $/,04.3?-8,,D,4+89 Unit inch 4922054=0/041,9-*04.52,9 Required space around the outdoor unit$/,-8544+5/90+,9398,30456,4 27-5/8 11-5/8 Air Intake 25/32 13/32 13-3/8 14-31/32  #04.2,4004922054  9*2,9545/90+,9 4522,8/4/,/,0./5-/,5+55840 9*2,9545/90+,9 Installation in front-rear rowsObstacles to the front and rear of unit  #04.2,4004922054Make a Hole How to Install the Indoor UnitTrical wiring or conduits are Remove the Rear Panel from the UnitHole Dia Install the Rear Panel on the WallIf Wooden Wall If Block, Brick, Concrete or Similar Type WallHow to remove the grille Removing and Installing the GrilleHow to replace the grille Shape the Indoor Side Tubing Wiring Instructions General precautions on wiringWire Size and Length Wiring Instructions for Inter-unit Connections For Outdoor Unit  For solid core wiring or F-cable How to connect wiring to the terminal For Indoor Unit For stranded wiring  Right-side tubing Mounting Left-side tubing Switching drain hose and drain capDrain cap Frame Fastening Method Do not supply power toTubing and wiring to the out To unmount indoor unitCover B How to Install the Outdoor UnitWiring Instructions for the Outdoor Unit Routing the Tubing and WiringUse of the Flaring Method Flaring Procedure with a Flare ToolTo 0.5 mm Adjust so that the amount of tube Refrigerant TubingTaping the Tubes Connecting Tubing between Indoor and Outdoor UnitsFinishing the Installation Insulation of Refrigerant TubingAir Purging Hex wrench before Be sure to completely insertAttempting to turn the valve How to Test Run the Air Conditioner  Pump Down  Basic Functions of the Service ValvesRemote Controller Installation Position  Service Valve ConnectionsAddress Setting of the Remote Controller Address SwitchDC1111-0

CS-KE30NKU, CS-KE36NKU, CU-KE30NKU, CU-KE36NKU specifications

The Panasonic CU-KE36NKU, CS-KE36NKU, CU-KE30NKU, and CS-KE30NKU air conditioning units represent the brand's commitment to delivering high-performance cooling solutions backed by innovative technologies. These units cater to both residential and commercial applications, ensuring users experience maximum comfort throughout the year.

One of the standout features of these models is their energy efficiency. Both units are equipped with advanced inverter technology, which allows for variable speed operation. This means they can adjust their power output according to the room's cooling needs, reducing energy consumption and minimizing electric bills while maintaining a consistent temperature. The models boast impressive SEER (Seasonal Energy Efficiency Ratio) ratings, making them environmentally friendly options.

Panasonic's nanoe-G technology is another remarkable feature incorporated into these models. This technology helps to purify the air by generating hydroxyl radicals, which eliminate airborne particles, odors, and harmful bacteria. This results in a healthier indoor environment, conducive to both comfort and well-being. The air purification aspect not only enhances the air quality but also extends the lifespan of the HVAC system by reducing the buildup of dust and contaminants.

In terms of user convenience, both the CU-KE and CS-KE series are equipped with programmable timers, allowing users to set their desired operation schedules. They also come with a remote control for ease of use, enabling adjustments from a distance. The installation process is straightforward, and the sleek design blends seamlessly with various interior aesthetics, making them a suitable choice for any room.

Durability is a key characteristic of Panasonic air conditioning units, and the CU-KE36NKU, CS-KE36NKU, CU-KE30NKU, and CS-KE30NKU are designed to withstand varying environmental conditions. Their robust construction ensures reliability and performance over the years. Additionally, both models come with a quiet operation feature that minimizes noise levels, allowing for comfortable use without disturbing daily activities.

In summary, the Panasonic CU-KE36NKU, CS-KE36NKU, CU-KE30NKU, and CS-KE30NKU are exceptional air conditioning units that combine energy efficiency, innovative purification technology, user-friendly features, and robust durability. These models are an ideal investment for anyone seeking a reliable and high-performance cooling solution.