Omron ne-c801 instruction manual Risk of Electrical Shock

Page 7

Safety Information

OPERATING THE DEVICE (continued)

Dispose of the device, components and optional accessories according to applicable local regulations. Unlawful disposal may cause environmental pollution.

Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device do not perform the expected specification or it may damage the unit.

Changes or modification not approved by Omron Healthcare will void the user warranty.

To avoid injury to the nose mucosa, do not squeeze the optional nosepiece into the back of the nose.

To avoid the medication residue on the face. After nebulization, be sure to wipe the face after removing the optional masks.

When using this device, there will be some noise and vibration caused by the pump in the compressor. There will also be some noise caused by the emission of compressed air from the nebulizer kit. This is normal and does not indicate a malfunction.

When sterilizing parts by boiling, make sure that the container does not boil dry.

Do not use the device while sleeping or if drowsy.

Do not block the slit between the cap and the inhalation air inlet.

Risk of Electrical Shock

Do not connect the AC adapter terminal using wire or other metallic conductors.

Do not use the compressor (main unit) or AC adapter while they are wet.

Do not plug or unplug the AC adapter into the electrical outlet with wet hands.

Do not immerse the compressor (main unit) in water or other liquid.

Do not spill water or other liquids on the compressor and AC adapter. These parts are not waterproof. If liquid spills on these parts, immediately unplug the AC adapter and wipe off the liquid with gauze or other soft absorbent material.

Do not use or store the device in humid locations, such as a bathroom. Use the device within the operating temperature and humidity.

Use only the AC adapter designed by Omron for this device. Use of any other AC adapter may damage the device.

Do not operate the device with a damaged power cord or plug.

Do not use a cellular phone near the device. It may result in an operational failure.

7

Image 7
Contents NE-C801 Contents Staple your purchase receipt here IntroductionIntended Use Operating the Device Safety InformationSafety Information Risk of Electrical Shock Maintenance and Storage Nebulizer Kit Compressor Main Unit Know Your UnitComponents Know Your UnitPreparing the Nebulizer for Use Preparing the Nebulizer for USE Using the Child Mask Optional Using the Nosepiece OptionalUsing the Adult Mask Optional Attaching the Air Tube Hold the nebulizer kit as illustrated on the right Using the DeviceUsing the Child Mask or the Adult Mask Optional Using the DeviceUsing the Device Cleaning after Each Use Handling the Baffle Daily DisinfectingInsert a new air filter Changing the Air FilterCaring for the Device Cause Troubleshooting GuideLimited Warranty FCC Statement Contents SpecificationsParticle Specifications Technical DataElectromagnetic emissions IEC60601-1-2 Guidance and Manufacturers DeclarationElectromagnetic immunity IEC60601-1-2 Recommend separation distance KHz to 80 MHz KHz to 800 MHz MHz to 2.5GHz Page Omron Healthcare, Inc