Omron ne-c801 instruction manual Maintenance and Storage

Page 8

Safety Information

Risk of Electrical Shock (continued)

Do not overload power outlets. Plug the AC adapter into the appropriate voltage outlet.

Do not use extension cords. Plug the AC adapter directly into the electrical outlet.

Unplug the AC adapter from the electrical outlet after using the device.

Remove the AC adapter from the device after use.

Unplug the AC adapter from the electrical outlet before cleaning the device.

Do not pull the power cord of AC adapter strongly.

Maintenance and Storage

Keep the device out of the reach of unsupervised infants and children. The device may contain small parts that can be swallowed.

Do not leave the cleaning solution in the nebulizer parts. Rinse the nebulizer parts with clean hot tap water after disinfecting.

Wash the nebulizer parts after each use. Dry the parts immediately after washing.

Do not store the air tube with moisture or medication remaining in the air tube. This could result in infection as a result of bacteria.

Store the device and the components in a clean, safe location.

Do not carry or leave the nebulizer kit with medication in the medication cup.

Do not place or attempt to dry the device, components or any of the nebulizer parts in a microwave oven.

Do not wrap the power cord around the compressor (main unit) and AC adapter.

8

Image 8
Contents NE-C801 Contents Introduction Staple your purchase receipt hereIntended Use Safety Information Operating the DeviceSafety Information Risk of Electrical Shock Maintenance and Storage Know Your Unit Nebulizer Kit Compressor Main UnitKnow Your Unit ComponentsPreparing the Nebulizer for Use Preparing the Nebulizer for USE Using the Adult Mask Optional Using the Nosepiece OptionalUsing the Child Mask Optional Attaching the Air Tube Using the Device Hold the nebulizer kit as illustrated on the rightUsing the Device Using the Child Mask or the Adult Mask OptionalUsing the Device Cleaning after Each Use Daily Disinfecting Handling the BaffleChanging the Air Filter Insert a new air filterCaring for the Device Troubleshooting Guide CauseLimited Warranty FCC Statement Specifications ContentsTechnical Data Particle SpecificationsGuidance and Manufacturers Declaration Electromagnetic emissions IEC60601-1-2Electromagnetic immunity IEC60601-1-2 Recommend separation distance KHz to 80 MHz KHz to 800 MHz MHz to 2.5GHz Page Omron Healthcare, Inc