2.4 FRONT OF THE METER (Continued)

METER BUTTONS

SETPTS Button

In the run mode, press this button to sequentially recall the previous setpoint settings. After using the /T1/T2 and /DEV buttons to alter these settings as desired, press the SETPTS button to store these new values.

Unless you press the SETPTS, /T1/T2 or /DEV button within 20 seconds to store your input, the meter will scroll to setpoint 2 the return to the run mode.

If the dual relay option is not installed or if the “L.3=1” on the “LK.CF” menu, pressing the SETPTS button will display the meter's firmware version.

/T1/T2 Button

In the run mode, pressing the /T1/T2 button will scroll to show T1, T2, and T1-T2.

During the configuration mode or Setpoint modes, use the /T1/T2 button to change the values of the flashing digit shown on the display and/or toggle between menu choices, such as "R.1=F" or "R.1=C". When configuring your setpoint values, press the /T1/T2 button to increment the flashing digit from 0 to 9 by 1's.

/DEV Button

In the run mode press the /DEV button to display the deviation of reading from Setpoint 1.

In the configuration or setpoint modes, press the /DEV button to scroll to the next digit.

6

Image 14
Contents User’s Guide Servicing North America Standard Procedures PrefacePage Iii Table of Contents Selecting Output Configuration OT.CF List of Figures Introduction UnpackingSafety Considerations EMC ConsiderationsDescription Standard FeaturesAbout the Meter Available Accessories Add-On OptionsFront of the Meter Shows the location of each part of the front of the meterMeter Buttons Setpts ButtonReset Button Front Panel Lockout Push Button Lockout Jumper LockoutConnector label ac Powered and dc Powered detail Back of the MeterBack of the Meter Connector Description Disassembly Disconnect the power supply before proceedingRATING/PRODUCT Label Main Board Power JumpersGetting Started Main Board Jumper Positions S3 Jumper Functions Mounting the Meter PlcsConnecting Sensor Input Through 3-7 illustrate how to connect you power sensorsConnecting Main Power Main Power Connections ac powered unitMain Power Connections dc powered unit Analog and Relay Output Connections11 Analog Output Connections Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Display /DEV Reset DescriptionMenu /DEV Setpoint Configuration Displays SetpointSpecifications Signal InputInput Power Information Analog Output if applicable Side View TOP View Factory Preset Values Menu Item Factory Preset ValuesCE Approvals Information WARRANTY/DISCLAIMER OMEGA…Of Course