ANALOG OUTPUT (if applicable)

Signal type:

Current or voltage

Signal level:

Current: 10 V max compliance at 20 mA output

 

Voltage: 20 mA max for 0-10 V output

Function:

May be assigned to a display range or proportional

 

control output with setpoint #1 when used as a

 

control output.

Linearity:

0.2%

Load Regulation:

1.1%

Line Regulation:

0.02% /V ac

Step Response Time:

2 - 3 seconds to 99% of the final value

ALARM OUTPUTS (if applicable)

2 Form "C" on/off relays. Configurable for latched and unlatched by software.

Max current:

5 AMPS, resistive load.

Max voltage:

250 V ac or 30 V dc

ISOLATED ANALOG OUTPUT (TB5, if applicable)

Same as non-isolated analog output except isolated to 1000 Vdc.

Signal Type:

Current or voltage

Signal Level:

Current: 10 V max compliance at 20 mA output

 

Voltage: 20 mA max for 0-10 V output

Function:

May be assigned to a display range or proportional

 

control output with setpoint #1 when used as a

 

control output.

Linearity:

0.2%

Step Response Time:

2 - 3 seconds to 99% of the final value

Only one analog output is available on each unit and it must be factory installed.

51

Image 59
Contents User’s Guide Servicing North America Preface Standard ProceduresPage Iii Table of Contents Selecting Output Configuration OT.CF List of Figures Unpacking IntroductionEMC Considerations Safety ConsiderationsDescription Standard FeaturesAbout the Meter Add-On Options Available AccessoriesShows the location of each part of the front of the meter Front of the MeterSetpts Button Meter ButtonsReset Button Jumper Lockout Front Panel Lockout Push Button LockoutBack of the Meter Connector label ac Powered and dc Powered detailBack of the Meter Connector Description Disconnect the power supply before proceeding DisassemblyRATING/PRODUCT Label Main Board Power JumpersGetting Started Main Board Jumper Positions S3 Jumper Functions Plcs Mounting the MeterThrough 3-7 illustrate how to connect you power sensors Connecting Sensor InputMain Power Connections ac powered unit Connecting Main PowerAnalog and Relay Output Connections Main Power Connections dc powered unit11 Analog Output Connections Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Display /DEV Reset DescriptionMenu /DEV Setpoint Setpoint Configuration DisplaysSignal Input SpecificationsInput Power Information Analog Output if applicable Side View TOP View Menu Item Factory Preset Values Factory Preset ValuesCE Approvals Information WARRANTY/DISCLAIMER OMEGA…Of Course