Omega DP26-RTD manual Back of the Meter Connector Description

Page 18

2.6 BACK OF THE METER (Continued)

 

 

 

 

Table 2-2 Connector Description

Connector

 

Description

 

 

TB1-1

 

Setpoint 1: Normally open (N.O.1) connection

 

TB1-2

 

Setpoint 1: Normally closed (N.C.1) connection

 

TB1-3

 

Setpoint 1: Common (COM1) connection

 

TB1-4

 

Setpoint 2: Normally open (N.O.2) connection

 

TB1-5

 

Setpoint 2: Normally closed (N.C.2) connection

 

TB1-6

 

Setpoint 2: Common (COM2) connection

 

TB1-7

 

ac line connection (no connections on dc-powered units)

 

TB1-8

 

ac neutral connection (+ Input on dc-powered units)

 

TB1-9

 

ac Earth ground (-dc-power return on dc-powered units)

 

TB1-10

 

Analog 1 voltage output

 

TB1-11

 

Analog 2 current output

 

TB1-12

 

Analog 3 return

 

 

 

 

 

 

TB2-1

 

+E2:

Positive excitation for input #2

 

TB2-2

 

+S2:

Positive signal input for input #2

 

TB2-3

 

-S2:

Negative signal input for input #2

 

TB2-4

 

-E2:

Negative excitation for input #2

 

TB2-5

 

+E1:

Positive excitation for input #1

 

TB2-6

 

+S1:

Positive signal input for input #1

 

TB2-7

 

-S1:

Negative signal input for input #1

 

TB2-8

 

-E1:

Negative excitation for input #1

 

 

 

 

 

TB5-1

 

Isolated Analog Voltage Output

 

TB5-2

 

Isolated Analog Current Output

 

TB5-3

 

Isolated Analog Output Return

 

 

 

 

 

10

Image 18
Contents User’s Guide Servicing North America Standard Procedures PrefacePage Iii Table of Contents Selecting Output Configuration OT.CF List of Figures Introduction UnpackingSafety Considerations EMC ConsiderationsStandard Features About the MeterDescription Available Accessories Add-On OptionsFront of the Meter Shows the location of each part of the front of the meterMeter Buttons Setpts ButtonReset Button Front Panel Lockout Push Button Lockout Jumper LockoutConnector label ac Powered and dc Powered detail Back of the MeterBack of the Meter Connector Description Disassembly Disconnect the power supply before proceedingMain Board Power Jumpers Getting StartedRATING/PRODUCT Label Main Board Jumper Positions S3 Jumper Functions Mounting the Meter PlcsConnecting Sensor Input Through 3-7 illustrate how to connect you power sensorsConnecting Main Power Main Power Connections ac powered unitMain Power Connections dc powered unit Analog and Relay Output Connections11 Analog Output Connections Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Reset Description Menu /DEVDisplay /DEV Setpoint Configuration Displays SetpointSpecifications Signal InputInput Power Information Analog Output if applicable Side View TOP View Factory Preset Values Menu Item Factory Preset ValuesCE Approvals Information WARRANTY/DISCLAIMER OMEGA…Of Course