Gentek 3940321, 3940200, 3950320, 3950202, 3940421, 3940320, 3940402 Qty Part Number Description

Page 79

Appendix A: Replacement Parts

Item

Qty.

Part Number

Description

1

1

3911000

Glass, Side

2A

1

3911900

Glass, Sash 2'

2B

1

3911901

Glass, Sash 3'

2C

1

3911902

Glass, Sash 4'

3A

1

3911800

Sash Assembly, 2'

3B

1

3911801

Sash Assembly, 3'

3C

1

3911802

Sash Assembly, 4'

4A

1

3905600

Lower Air Foil, 2'

4B

1

3905601

Lower Air Foil, 3'

4C

1

3905602

Lower Air Foil, 4'

5A

1

3907400

Bracket, Air Foil R.H.

5B

1

3907401

Bracket, Air Foil L.H.

6A

1

3907500

Stop, Sash R.H.

6B

1

3907501

Stop, Sash L.H.

7A

1

6916500

Latch, Sash

7B

1

3906700

Bracket, Latch

7C

1

1927403

Spring, Compression Latch

7D

2

1893206

Screw, 8-32 x .38" Lg. Phillips Pan S.S. Type F

8A

1

3776003

Bag, 2' – for Bag-In/Bag-Out on XPert

8B

1

3776004

Bag, 3' – for Bag-In/Bag-Out on XPert

8C

1

3776005

Bag, 4' – for Bag-In/Bag-Out on XPert

9A

2

1889316

Screw, 10-24 x 1.00 PH Phil S.S.

9B

2

1912108

Washer, Plastic .194 ID. x .380 OD

9C

2

7868402

Bushing, Spacer .31 x .63

10

1.9 Ft

6913700

Wiper, Sash Seal

11A

2

1936800

Bushing, Heyco closed 1.50 Dia.

11B

2

1934601

Bushing, Heyco w/ Flex Shutter 1.50 Dia.

12A

1

3915401

Side Air Foil

12B

2

1889912

Screw, #6-32 x .75" Oval Hd. Type F (S.S.)

13A

1

3907700

Reflector, Light 2'

13B

1

3907701

Reflector, Light 3'

13C

1

3907702

Reflector, Light 4'

13D

2

1889308

Screw, Mach. 10-24 x .50 PH Phillips

14A

1

3708300

Lamp, Fluorescent 2' Enclosure (F15T8-SP35)

14B

1

9721902

Lamp, Fluorescent 3' Enclosure (F17T8)

14C

1

9721901

Lamp, Fluorescent 4' Enclosure (F25T8)

16A

1

3911700

Bracket, Right Reflector Support

16B

1

3911701

Bracket, Left Reflector Support

16C

4

1893108

Screw, #8 x 1/2 AB Hex Washer Head

74

Image 79
Contents User’s Manual USA Warranty Prerequisites Able OntentsMaintaining Your Filtered Enclosure Chapter Introduction Introduction About This Manual Typographical Conventions Chapter Prerequisites Support, Vibration and Movement Requirements Temperature Variation RequirementsBackground on Electrostatics or Static Electricity Humidity and Static Electricity RequirementsExhaust and Blower Requirements Location and Air Current RequirementsSurface Resistivity Table XPert Station Space Requirements Electrical RequirementsLift by the front air foil Chapter Getting StartedDo not move the enclosure by tilting it onto a hand truck Unpacking the EnclosureWork Surface and Hepa Filtered Enclosure Installation Work Surface SpecificationsFiltered Enclosure Installation XPert Station Getting Started Getting Started Carbon Filters Accessory for Odor Control only Installation of Hepa Filters Accessory Odor Control CarbonHepa Filters 115V Models Filter Type Appropriate UseGetting Started Validating the Vented Enclosure Set the Face Velocity with the Speed Control AdjustmentSealing the Filtered Enclosure to the Work Surface High Performance Features Chapter High Performance Features and Safety PrecautionsHigh Performance Features and Safety 1510 Hepa Filtered Enclosure Airflow Diagram High Performance Features and Safety High Performance Features and Safety High Performance Features and Safety High Performance Features and Safety Safety Precautions High Performance Features and Safety High Performance Features and Safety High Performance Features and Safety Planning Routine Daily Work ProceduresFinal Purging Start-upLoading Materials and Equipment Work TechniquesHepa Filter Applications Suitability and Guidelines Suitable ApplicationsShutdown Odor Control Carbon Filter Applications sold as an accessory Definition of Terms Appropriate Chemicals for Odor Control Carbon Filters Prohibited Acid Use Chemical Carcinogen Use with Odor Control Carbon FiltersBalance Station, which uses a remote blower Chapter Maintaining Your Filtered Enclosure Weekly Routine Maintenance ScheduleMonthly or more often as required Decontamination Determination of when to Replace Hepa FiltersAnnually Maintaining Your Filtered Enclosure Purpose Hepa Filter Leak TestMineral oil Catalog #1491400 Acceptance Calibrate and Operate the Airflow Monitors Labconco Airflow Monitor / Airflow Switch OperationGuardian Airflow Monitor LED Monitor Calibration Enclosure Operating In-Flow Alarm Condition Set Point SpeedGuardian Digital 1000 Airflow Monitor Guardian Airflow Monitor LED with Airflow SwitchDigital 1000 Calibration OperationFactory Settings Guardian Digital 1000 Airflow Monitor Maintaining Your Filtered Enclosure Odor Control Carbon Filter Replacement Procedure See Steps for Calculating PPM and Filter Life Calculating Odor Control Carbon Filter LifeAmmonia only Initial CertificationRe-Certification Formaldehyde onlyMotorized Impeller Replacement Fluorescent Light ReplacementMotorized Impeller Replacement Speed Control Replacement Work Surfaces Chapter Accessorizing Modifying Your Filtered EnclosureAirflow Monitor Add appropriate Front Panel with cutout to mount DigitalExhaust Transition Kits for Ducting to Outside Remote Blowers Part DescriptionOdor Control Carbon Filter Accessory Filters Hepa FilterExhaust Dampers Hepa Filter Bag-In/Bag-Out BagUtility Shelf Kit Storage CabinetsAccessorizing and Modifying your Filtered Enclosure Problem Cause Corrective Action Chapter Troubleshooting Servicer Operating LOGTroubleshooting Problem Cause Corrective Action Date Comments Service Operating Record LogAppendix a Filtered Enclosure Components Replacement Parts Qty Part Number Description Qty Part Number Description Long Use for XPert System and XPert Station Use for XPert System, XPert Station, Digital Monitor and Bag Appendix B Dimensions Exhaust Options Figure B-1 XPert Filtered Balance System Figure B-2 XPert Filtered Balance Station Appendix B Dimensions and Exhaust Options Environmental Conditions Appendix C Filtered Enclosure SpecificationsAppendix C Filtered Enclosure Specifications Appendix C Filtered Enclosure Specifications Appendix C Filtered Enclosure Specifications Appendix C Filtered Enclosure Specifications Appendix C Filtered Enclosure Specifications Model Size Ppendix Uick Hart Iltered NclosuresNon-mandatory recommendations from Prudent Practices Appendix E References Nfpa 30 2000 Flammable and Combustible Liquids Code General References Laboratory Safety, Principles and Practices, American Page USA