<Chapter 6> Special Function

6-1 Animal Scale Function Setting

2CFN-05 = 1

(Animal Scale Mode1: No weight display under unstable status)

When no any object is on the platter, the screen will display:

When the object is on the platter, after weight has been measured, the screen will display:

.

If the display weight value keeps being lower than zero plus 10d, the screen will display:

2 CFN-05 = 2

(Animal Scale Mode 2: Weight display weather under unstable or stable status)

When the weight value reaches the range of CFN-06 and CFN-07 setting, the screen will keep displaying the weight value.

When the weight value is over the range of CFN-06 and CFN-07 setting, the screen will display the normal weight measurement.

Example: CFN-06=30

CFN-07=2

WT

 

 

Weight Holding

 

重量保持

30d

 

 

Weight消重量Holding保持 Cancellation

10d

T

 

32 Times

FM User Manual

21

SME300000119

Image 22
Contents SME300000119 Table of Content Transmission Interface Safety Precaution Before Using the IndicatorFeatures and Specification FeaturesDigital Specification SpecificationAnalog Specification Power RequirementKeypad Operation Instruction Function Operation DescriptionIndication Front & Rear PanelsFront Panel KeypadRear Panel Wired 5-wired Load Cell Chapter InstallationLoad Cell Dimension Battery Assembly Internal Calibration Specification Setting Parameter CodeSetting Specification Parameter DescriptionDescription Display Decimal Point Digit None Weight Calibration WeightPassword Setting Internal Function Setting Internal Function Parameter Description Function SettingParameter Description Error Message Animal Scale Function Setting Special FunctionCFN-08 = 0 ⇒ Multi-interval Dual Range Resolution Switch FunctionCFN-08 = 1 ⇒ Multi-range FNC-02 or FNC-03 setting is at parameter 5. HR Resolution Switch FunctionPre-tare Cancellation Pre-tare FunctionOP-01 RS232/RS485 Serial Output with RTC Transmission InterfacePin Allocation of Rear Panel Connection Description RS485 Function Parameter Setting To escape Function Parameter Setting RS232 Setting Press Enter Input the *Parameter code intendedOP-01 RS232 / RS485 Interface Function Parameter Function CodeNo Limit Times/sec Transmission Format CR LFCommand Mode Command FunctionDefault Recovery for General Function Parameters MaintenanceDefault Recovery for All Parameters Self-diagnosis ModeEeprom Testing 2 7-segment Display TestingKeypad & Calibration Switch Testing RTC Time & Date Testing