Excell Precision FM user manual Function Parameter Setting

Page 29

EXCELL PRECISION CO., LTD.

2Function Parameter Setting

Parameter

Function

 

Setting

Default

Parameter

Description

Code

 

Setting

FNC-00

FNC-01

FNC-02

FNC-03

FNC-04

Key Disable

DSP Update

F1 Key

Function

Setting

F2 Key

Function

Setting

Backlight

Setting

0000

0

ON

0000 is corresponding to:

 

 

 

GROSS

F2

 

 

1

OFF

ZERO TARE

 

1111

NET

(from left to right)

 

3

4

0

 

 

 

No Limit

 

1

 

 

20 times/sec.

2

 

 

10 times/sec.

3

 

 

5 times/sec.

 

4

 

 

1 times/sec.

 

0

 

 

Print (printing)

1

 

 

Units (units switch)

2

 

M+ (accumulation and printing)

3

 

 

MC (memory clearing)

4

 

Weight/Weight Accumulation/Times

 

 

Accumulation Display Switch

 

 

 

5

 

 

HR (high resolution switch)

6

 

 

Pre-tare (pre-tare function)

0

 

 

Print (printing)

1

 

 

Units (units switch)

2

 

M+ (accumulation and printing)

3

 

 

MC (memory clearing)

4Weight/Weight Accumulation/Times Accumulation Display Switch

5

HR (high resolution switch)

6

Pre-tare (pre-tare function)

0

Auto Backlight On

(backlight on in operation only)

 

1

Backlight On (backlight always on)

2

Backlight Off

0000

1

0

1

0

FM User Manual

28

SME300000119

Image 29
Contents SME300000119 Table of Content Transmission Interface Before Using the Indicator Safety PrecautionFeatures Features and SpecificationAnalog Specification SpecificationDigital Specification Power RequirementFunction Operation Description Keypad Operation InstructionFront Panel Front & Rear PanelsIndication KeypadRear Panel Load Cell Chapter InstallationWired 5-wired Load Cell Dimension Battery Assembly Internal Calibration Parameter Code Specification SettingDescription Specification Parameter DescriptionSetting Display Decimal Point Digit None Weight Weight CalibrationPassword Setting Internal Function Setting Parameter Description Function SettingInternal Function Parameter Description Error Message Special Function Animal Scale Function SettingCFN-08 = 1 ⇒ Multi-range Dual Range Resolution Switch FunctionCFN-08 = 0 ⇒ Multi-interval Pre-tare Cancellation Resolution Switch FunctionFNC-02 or FNC-03 setting is at parameter 5. HR Pre-tare FunctionPin Allocation of Rear Panel Transmission InterfaceOP-01 RS232/RS485 Serial Output with RTC Connection Description RS485 Function Parameter Setting To escape Function Parameter Setting Press Enter Input the *Parameter code intended RS232 SettingParameter Function Code OP-01 RS232 / RS485 Interface FunctionNo Limit Times/sec CR LF Transmission FormatCommand Function Command ModeDefault Recovery for All Parameters MaintenanceDefault Recovery for General Function Parameters Self-diagnosis ModeKeypad & Calibration Switch Testing 2 7-segment Display TestingEeprom Testing RTC Time & Date Testing