Excell Precision FM Analog Specification, Digital Specification, Optional Interface

Page 6

EXCELL PRECISION CO., LTD.

1-2 Specification

Analog Specification

Load Cell Current: DC 5V ±5% 60mA (Up to Four 350Ω Load Cells)

Max. Load Cell Input Voltage: 16 mV

Input Sensitivity: 0.12μV/D or more

Conversion Rate: Approximately 100 times/sec. (max.)

Resolution: 19 bits

Digital Specification

Display: LCD, 6 digits, height 25.4x10mm, LED backlight

Display Frequency: 50 times/sec. (max.)

Display Range: - 999999 ~ 999999

Min. Division: 1, 2, 5, 10, 20, 50

Decimal Point: 0, 0.0, 0.00, 0.000, 0.0000

Memory: Calibration parameter and function setting are all stored in EEPROM.

Optional Interface

OP-01 RS-232 / RS-485 (Includes RTC Function)

Power Requirement

Adaptor Spec.: Input 120/230VAC 50~60Hz, output 9V/1000mA

6V/5pcs Hi-MH rechargeable battery kit (1800mA/1hr)

Max. Power Consumption (by rechargeable battery):

120mA (with 4 Load Cells + backlight + RS-232 interface) →15 hours 50mA (with 1 Load Cell + no backlight + no RS-232 interface) →36 hours

Others

Operation Temperature: -10~ 40

Operation Humidity: < 85% R.H.

Dimension: W 49.5 × L193 × H134 (mm)

Weight: 700 (g)

FM User Manual

5

SME300000119

Image 6
Contents SME300000119 Table of Content Transmission Interface Safety Precaution Before Using the IndicatorFeatures and Specification FeaturesDigital Specification SpecificationAnalog Specification Power RequirementKeypad Operation Instruction Function Operation DescriptionIndication Front & Rear PanelsFront Panel KeypadRear Panel Chapter Installation Wired 5-wired Load CellLoad Cell Dimension Battery Assembly Internal Calibration Specification Setting Parameter CodeSpecification Parameter Description SettingDescription Display Decimal Point Digit None Weight Calibration WeightPassword Setting Internal Function Setting Function Setting Internal Function Parameter DescriptionParameter Description Error Message Animal Scale Function Setting Special FunctionDual Range Resolution Switch Function CFN-08 = 0 ⇒ Multi-intervalCFN-08 = 1 ⇒ Multi-range FNC-02 or FNC-03 setting is at parameter 5. HR Resolution Switch FunctionPre-tare Cancellation Pre-tare FunctionTransmission Interface OP-01 RS232/RS485 Serial Output with RTCPin Allocation of Rear Panel Connection Description RS485 Function Parameter Setting To escape Function Parameter Setting RS232 Setting Press Enter Input the *Parameter code intendedOP-01 RS232 / RS485 Interface Function Parameter Function CodeNo Limit Times/sec Transmission Format CR LFCommand Mode Command FunctionDefault Recovery for General Function Parameters MaintenanceDefault Recovery for All Parameters Self-diagnosis ModeEeprom Testing 2 7-segment Display TestingKeypad & Calibration Switch Testing RTC Time & Date Testing