Excell Precision FM user manual OP-01 RS232 / RS485 Interface Function, Parameter Function Code

Page 31

EXCELL PRECISION CO., LTD.

2OP-01 RS232 / RS485 Interface Function

Parameter Function Code

Information

RS1-00 Pattern

Transmission

RS1-01 Method

Transmission

RS1-02 Rate

Parity

RS1-03

Bit Length

Stop Bit

RS1-04

Unstable or

Over Load

 

Auto

RS1-05Transmission

Condition

Command

RS1-06 Address

Output

RS1-07 Format

 

Setting

 

 

Parameter

 

Description

0

Display Correspondingly

1

 

Gross Weight

2

 

Net Weight

3

 

 

Tare

 

4

Weight Accumulation

5

Times Accumulation

6

Output with Date & Time

0

Continuous Transmission

1

Auto Transmission

 

 

 

 

 

 

2

Press

F1

or

F2

to transmit

 

4

3Command Mode (no address)

4Command Mode (with address)

0

 

1200

1

 

2400

2

 

4800

3

 

9600

4

 

19200

 

 

No Parity

0

N, 8, 1

8 Bits Length

 

 

1 Stop Bit

 

 

Odd Parity,

1

O, 7, 1

7 Bits Length,

 

 

1 Stop Bit

 

 

Even Parity,

2

E, 7, 1

7 Bits Length,

 

 

1 Stop Bit

0

 

Continuous Output

1

 

Stop Output

0

 

Positive (over + 10D)

1

 

Positive/negative

(over + 10D, under - 10D)

 

00

 

 

Available only if RS1-01 setting is “4”

99

0

Standard Format

1

UMC 600

Default Setting

0

0

1

2

0

0

0

0

FM User Manual

30

SME300000119

Image 31
Contents SME300000119 Table of Content Transmission Interface Before Using the Indicator Safety PrecautionFeatures Features and SpecificationPower Requirement SpecificationAnalog Specification Digital SpecificationFunction Operation Description Keypad Operation InstructionKeypad Front & Rear PanelsFront Panel IndicationRear Panel Wired 5-wired Load Cell Chapter InstallationLoad Cell Dimension Battery Assembly Internal Calibration Parameter Code Specification SettingSetting Specification Parameter DescriptionDescription Display Decimal Point Digit None Weight Weight CalibrationPassword Setting Internal Function Setting Internal Function Parameter Description Function SettingParameter Description Error Message Special Function Animal Scale Function SettingCFN-08 = 0 ⇒ Multi-interval Dual Range Resolution Switch FunctionCFN-08 = 1 ⇒ Multi-range Pre-tare Function Resolution Switch FunctionPre-tare Cancellation FNC-02 or FNC-03 setting is at parameter 5. HROP-01 RS232/RS485 Serial Output with RTC Transmission InterfacePin Allocation of Rear Panel Connection Description RS485 Function Parameter Setting To escape Function Parameter Setting Press Enter Input the *Parameter code intended RS232 SettingParameter Function Code OP-01 RS232 / RS485 Interface FunctionNo Limit Times/sec CR LF Transmission FormatCommand Function Command ModeSelf-diagnosis Mode MaintenanceDefault Recovery for All Parameters Default Recovery for General Function ParametersRTC Time & Date Testing 2 7-segment Display TestingKeypad & Calibration Switch Testing Eeprom Testing