Excell Precision FM user manual Internal Function Setting, Parameter Code

Page 19

EXCELL PRECISION CO., LTD.

5-3 Internal Function Setting

Press ENTER

*Parameter Code

 

Tare or Zero Function under

 

Unstable Status

Input the *Parameter

Turning on Re-zero

 

code intended

Re-zero Range

 

 

Filter Strength

Press ENTER

AD Sampling Rate

 

 

Animal Scale Mode

The screen displays

Animal Scale Stable Range

the parameters set

 

previously. Input the

 

parameters intended

Animal Scale Sampling

and then press ENTER

Frequency

 

Dual Range Resolution

Setting

 

 

 

Dual Range Resolution

 

 

 

Middle Point Setting

Continue other functions setting

 

 

or press

to escape.

ZERO

To add the value flashing

 

ESC

 

 

 

 

 

TARE

To reduce the value flashing

 

 

GROSS

To move the cursor leftward

 

 

NET

 

 

3

 

 

 

F2

To move the cursor rightward

 

 

4

 

 

ENTER

Storage setting

 

 

 

 

 

ESC

To abort setting / escape

FM User Manual

18

SME300000119

Image 19
Contents SME300000119 Table of Content Transmission Interface Before Using the Indicator Safety PrecautionFeatures Features and SpecificationPower Requirement SpecificationAnalog Specification Digital SpecificationFunction Operation Description Keypad Operation InstructionKeypad Front & Rear PanelsFront Panel IndicationRear Panel Wired 5-wired Load Cell Chapter InstallationLoad Cell Dimension Battery Assembly Internal Calibration Parameter Code Specification SettingSetting Specification Parameter DescriptionDescription Display Decimal Point Digit None Weight Weight CalibrationPassword Setting Internal Function Setting Internal Function Parameter Description Function SettingParameter Description Error Message Special Function Animal Scale Function SettingCFN-08 = 0 ⇒ Multi-interval Dual Range Resolution Switch FunctionCFN-08 = 1 ⇒ Multi-range Pre-tare Function Resolution Switch FunctionPre-tare Cancellation FNC-02 or FNC-03 setting is at parameter 5. HROP-01 RS232/RS485 Serial Output with RTC Transmission InterfacePin Allocation of Rear Panel Connection Description RS485 Function Parameter Setting To escape Function Parameter Setting Press Enter Input the *Parameter code intended RS232 SettingParameter Function Code OP-01 RS232 / RS485 Interface FunctionNo Limit Times/sec CR LF Transmission FormatCommand Function Command ModeSelf-diagnosis Mode MaintenanceDefault Recovery for All Parameters Default Recovery for General Function ParametersRTC Time & Date Testing 2 7-segment Display TestingKeypad & Calibration Switch Testing Eeprom Testing