4. Maintenance
The osmosis treatment unit runs completely automatically and maintenance is minimal. The only essential operation is periodic replacement of the filter cartridges.
IMPORTANT
Replace the
Replacing the pre-filter:
Filter cartridge replacement procedure
-Shut off power;
-Close the side cocks (RL);
-Vent the circuit from the top cap (S);
-Unscrew the filter housing (use the special wrench supplied in the accessories bag). Place a container to drain the water in the filter into;
-Fit the new cartridge and check it is correctly seated;
-Close vent S and open the side cocks RL;
-Check for leaks and water in the bottom of the appliance;
-Dry it off thoroughly.
Replacing the membranes:
Cartridge replacement procedure.
-Shut off power;
-Disconnect all hoses from the membrane housings, unscrew the base, and place a container to catch the water contained in the cartridges;
-Refit the membrane, check the seating of the
-Do not apply excessive force;
-Fit the new cartridge and check it is correctly seated;
-Start the unit up and check for leaks.