B) Osmosis-treated water not produced
Possible | Subcause | Solution | Display | ||
alarm | |||||
causes | |||||
|
|
| message | ||
|
|
|
| ||
|
|
| Check power supply and power switch ON |
| |
| No electrical power |
| (see “Positioning and installation”) |
| |
|
|
|
| ||
|
|
| Power plug not inserted in electrical panel |
| |
|
|
| (insert) |
| |
| No power to pump |
| Check connections and whether board is | none | |
|
| sending a signal | |||
|
|
| |||
|
|
| Pump condenser faulty (replace) |
| |
| Intake pressure switch faulty (jammed on full) |
| Replace, or adjust the pressure with the |
| |
|
| adjuster screw (fig.5) |
| ||
|
|
|
| ||
| Vat level switch (low) faulty (jammed on full) |
| Max level switch faulty, does not send |
| |
|
| production enable signal (replace/clean) |
| ||
Osmosis pump |
|
| (see wiring diagram) |
| |
|
| - Supply cock closed OPEN; |
| ||
not running |
|
|
| ||
|
|
| - Supply filter blocked CLEAN |
| |
|
|
| - Supply pressure should be > 1.5 bar |
| |
| No water supply or supply pressure/flow |
| - |
| |
|
| OPEN (see maintenance section) | Low pressure | ||
| inadequate |
| - Filter blocked – REPLACE (fig.5) | ||
|
|
| |||
|
|
| - Filler solenoid valve faulty or no power – |
| |
|
|
| REPLACE IF FAULTY (fig.5) |
| |
|
|
| - Intake pressure switch faulty (jammed on |
| |
|
|
| empty) – REPLACE (fig.5) |
| |
| Water in vat |
| Vat level switch (high) faulty, does not | Flooding | |
|
|
| |||
|
|
| switch to full: continues producing with | alarm | |
|
|
| overflow. REPLACE (see wiring diagram) |
| |
|
|
|
|
| |
| Water supply too cold (<10°) |
| Increase supply temperature |
| |
|
|
|
|
| |
|
| Replace |
| ||
|
| section) |
| ||
|
|
|
| ||
|
|
|
|
| |
| Membranes blocked |
| Replace membranes (see maintenance |
| |
|
| section) |
| ||
Osmosis pump |
|
|
| ||
|
|
|
| ||
Impeller damaged/broken |
| Check pressure gauge reading |
| ||
running but |
| if > 8, replace pump or impeller as |
| ||
production low |
|
| required |
| |
| Bypass valves need adjustment |
| See special adjustments section |
| |
|
|
|
|
| |
| Discharge pipe crimped |
| Route pipe properly |
| |
|
|
|
|
| |
| Pressure drop in vat supply hoses |
| Shut off power, dry thoroughly and repair |
| |
|
| leak |
| ||
|
|
|
| ||
|
|
|
|
|
- 43 -