Kenmore 625.38356 SET Presenttime of DAY, SET Water Hardness Number, SET Regeneration Time

Page 18

SET PRESENTTIME OF DAY

If the words PRESENT TIME do not show in the display, press the SELECT button until they do show in the display. Press the UP or DOWN buttons to set the present time. Press UP to move the display ahead; press DOWN to move the time backward. If the present time is between noon and midnight, be sure PM shows. If the present time is between midnight and noon, be sure AM shows. Each press of the UP or DOWN buttons changes the time by one (1) minute. Holding the buttons in changes the time 32 minutes each second.

SET WATER HARDNESS NUMBER

To set the water hardness number, complete the following steps:

1.Press the SELECT button once to display 25 (flashing) and HARDNESS. The grains per gallon (gpg) hardness of your water supply is on your water analysis report. Be sure to enter water test results on the Facts & Figure Chart on page 3.

2.If your water supply contains iron, compensate for it by adding to the water hardness number. For example, assume your water is 20 gpg hard and contains 2 ppm iron. Add 5 to the hardness number for each I ppm of iron.

In this example, you would use 30 for your hardness num- ber.

2ppmironx5= 10

20 gpg hardness

+10

30 HARDNESS NUMBER

,Press the UP or DOWN buttons to set your water hard- ness number in the display. The DOWN button moves the display to 1. The UP button moves the display to the high- est setting (see maximum setting for your model in the specifications).

NOTE: Each press of the UP or DOWN button changes the display by 1 between 1 and 25. Between 25 and the highest number, the display changes 5 at a time (25, 30, 35, etc.) Holding the UP or DOWN button in changes the display twice each second.

,_-- 'TPM

q, _-10

PRESENTTIME

I I,--IF AM

i i'DO

PRESENT TIME

FIG. 26

HARDNESS

L--I,I--I--IAM

'UU

RECHARGE

TIME

1:28o

_=: mm

==i

_7_ FE_

FIG. 27

SET REGENERATION TIME

To complete setting the regeneration time, complete the fol- lowing steps:

1.Press the SELECT button to display 2:00 AM (flashing) and RECHARGE TIME.

,At the 2:00 AM recharge time setting, the softener begins regeneration (see pages 26 - 28) at 2:00 AM. This is a good time in most households because water is not being used. If a different recharge time setting would be better for your household, complete the following step.

3.Press the UP or DOWN buttons to set the desired recharge starting hour. Be sure to observe the AM-PM as you did when setting the present time of day.

Note: Each press of the UP or DOWN buttons changes the display one hour. Holding the but-

tons in changes the display twice each sec- ond.

4.Press the SELECT button once again, to com- plete initial programming, and the current time of day shows in the display.

Questions? Call The Kenmore Water Line 1-800-426-9345

18

Image 18
Contents Repair or Parts ? Call toll free Save this ManualONE Year Limited Warranty on Water Softener TEN Year Limited Warranty Against LeaksDisclaimer of implied warranties limitation of remedies Questions? Page Inspectshipment Parts DescriptionsSmall Parts Tools Needed Proper Order to Install Water Treating EquipmentPlan Your Installation PipeWhere to Install the Water Softener ValveSuggested Slab Foundation Installation Draw Your Pipes FittingsDip Before Installing Checks & Tests Adding a pressure reducing valve may reduce the flowAssemble Inlet Outlet ADAPTORS, or Single Bypass Valve Bypass ValveInlet and Outlet Threaded Adaptors Clips Installing HoldingValve Bypass Bypass Valve Turned DownwardPosition Softener Into Place Connect the SoftenerConnect the Valve Drain Hose Connect Salt Tank Overflow TubingIII House Main Water Shutoff Valves Leak TestConnecting Transformer Installgroundingclampbetween Thesoftenerinand OUT PipesWater Meter Jumper Wire Cold Water Pipe GroundingShows, refer to the Troubleshooting Section InstallcoversProgram the Timer Restart the Water HeaterHardness Number SET Presenttime of DAYSET Water Hardness Number SET Regeneration TimeSanitize the Water Softener Sanitize Your Water Softener AS FollowsAddingsalttothe Storagetank Water Softening Salt with IronRemoving Additives Check List of STEP-BY-STEP Guides to Install Has Salt been added to Salt tank? Unit been sanitized? SeeExtrarecharge Recharge NOWOptional Settings Salt Efficiency 12 / 24 Hour ClockCalifornia Efficiency Requirement Water Flow Through the Softener Kenmores Ultra Cleansing Feature Recharge Time Remaining and Valve Position IndicatorsError Code Program MemorySoft Water Service and Regeneration ServiceRegeneration Water Flow Through Softener Brining and Brine Rinse Water Flow Through Softener in BackwashSoft Water Service and Regeneration Automatic Bypass Water Flow Through Softener Fast RinseElectronics Salt Bridge Salt BridgeKeeping the Water Softener Clean Nozzle & Venturi Cleaning Nozzle & VenturiIron from Resin BED Drain ALL Water from Softener Protect the Water Softener from FreezingProblemcause Checklist to Help YOU Save MoneyCorrection Model 38356 Timer Code S Model 39356 Timer Code S Bypass ValvesInches Pressure Drop PSI vs. Flow Rate GPM Flow Rate GPMAlways Make These Initial Checks First Eration CheckManual Initiated Electronics Diagnostics Possible ProblemProcedure for Removing Error Code From Faceplate Code Most LikelyOther Information Troubleshooting Valve Position IndicatorsTimer PWA Replacement ModelManualadvanceregeneration Check Checks, and the manual initiated diagnosticsBrine Valve Float Setting Cycle Flow Rates Gallons PER MINAssembly Rotary Valve ServiceDisassembly To Relieve PressureFill Cycle Valve Service CycleWater Flow Through the Softener Brining and Brine Rinse CycleBackwash Cycle Valve Backwash CycleFast Rinse Cycle Fast Rinse CycleRating Decal Location Water Softener Complete Part Number Part DescriptionINLET-OUTLET Grounding Clamps Brine Valve Assembly 4212 Wear-Strip Seal Cross-Section View No. Number Part Description Your Home
Related manuals
Manual 48 pages 28.32 Kb