CONNECT THE VALVE DRAIN HOSE

Take a length of 3/8" inside diameter drain tubing and attach one end to the drain fitting. See Fig. 16. Use a tube clamp to hold it in place. Put the other end of the tubing over a floor drain, into a laundry tub, standpipe, or other suitable drain. Check your local codes.

Leave an air gap of about 1-1/2" between the end of the hose and the drain. This gap is needed so you don'tget a backflow of sewer water into the softener. Do not put the end of the hose into the drain or con- nect without the air gap.

Place and support the hose so it does not kink or have sharp bends. Secure the hose end so water pressure does not cause the hose to "whip". Tie or wire it in place. Do not pinch the hose shut. The softener will not work if this drain hose is pinched, plugged, closed or restricted in any way. Direct drain flow

down into drain from drain line as flow could possibly over shoot the drain cover.

Keep the hose lower than the drain fitting. In some homes, to get to a drain you must raise the hose and run it overhead. If you need an overhead drain, do not raise the hose more than 8'above the floor. A copper drain tube is best to use.

COPPER DRAIN TUBE: Local plumbing codes may require the use a copper valve drain tube. A copper

tube is also best to use for an overhead drain. Use a copper drain tube if the softener is installed outside, or in the sunlight. Heat from the sun can soften, flatten and close up some kinds of tubes.

To adapt a copper drain tube to the softener, buy a compression fitting (1/4" female pipe threads x 1/2" O.D. tube) and tubing from your local hardware store.

CONNECT SALT TANK OVERFLOW TUBING

1.Locate the rubber grommet, tube adaptor and tube clamp (see Fig. 16) that are in the parts bag.

2.Push the grommet into the hole in the salt tank wall so half is inside and half is outside.

3.Push the bigger end of the tube adaptor into the grommet.

4.Push one end of a length of 3/8" I.D. tubing onto the tube adaptor, using the tube clamp to hold it in place.

5.Put the other end of the tubing over the floor drain.

IMPORTANT: Overflow water must run downward through the tubing. Do not raise the tubing higher than the grommet and tube adaptor. See Fig. 16. IMPORTANT: Do not connect to the valve drain hose you installed in step 1. Both drains must have a separate hose or tube.

NOTE: Overflow drain tubing is available from Sears. See parts list in back of manual

 

 

 

 

 

 

_,_//_

]1/4NPT

Threads

 

 

 

 

 

 

 

 

 

 

 

 

 

Barbs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/2" Outside

Diameter

 

 

 

 

 

 

 

 

 

 

 

 

 

Copper

Tube

 

 

 

 

 

 

 

 

 

 

 

 

 

(Not furnished)

 

 

 

 

 

Cut Barbs from Drain_

 

 

 

 

 

 

 

 

 

 

 

Fitting (Pull

clip

and

 

 

 

 

 

 

 

 

 

 

"emove fitting

from

valve.)

 

 

 

 

 

 

 

 

 

 

 

Comp

Fitting. 1/4

NPT

 

 

 

 

Grommet

Tube /

 

\_._

 

 

 

(Not furnished)

 

 

 

 

 

-I_

A daptclr

 

 

 

 

 

 

 

 

 

 

 

 

 

•"

_be

 

 

 

 

point

other

STANDPIPE

 

 

 

 

 

 

 

,%,

than

floor

 

 

 

 

 

 

 

 

 

 

 

drain.

 

 

 

 

 

 

 

 

 

 

 

 

"_""-_ Support

 

 

 

 

 

 

 

II

//

Valve Drain

Hose

place

as

llAir

-i!-

Gap

 

 

 

needed.

 

_

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

II

III

Tie

or Wire

1-1/2"

tubing

in

 

1-1/2"

 

NOTE:

Overflow

I I

I II

Tubing

in Place

Air Gap_

 

 

....

 

 

1-1/2" Air Gap

 

 

 

a0,e,ro\ Sears

)/__._

 

/

 

"b

 

_

 

 

 

 

drain

tubing is avail-

11

 

 

 

 

 

 

 

Item No. 42-3433

 

 

 

 

 

 

 

 

 

 

 

 

 

(20 ft).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Overflow

Drain Tubing --_'

 

OO_N

 

 

 

 

NDRY TUB

 

 

 

FIG. 16

Questions? Call The Kenmore Water Line 1-800-426-9345

14

Image 14
Contents Repair or Parts ? Call toll free Save this ManualDisclaimer of implied warranties limitation of remedies ONE Year Limited Warranty on Water SoftenerTEN Year Limited Warranty Against Leaks Questions? Page Small Parts InspectshipmentParts Descriptions Tools Needed Proper Order to Install Water Treating EquipmentPlan Your Installation PipeWhere to Install the Water Softener ValveSuggested Slab Foundation Installation Draw Your Pipes FittingsDip Before Installing Checks & Tests Adding a pressure reducing valve may reduce the flow Inlet and Outlet Threaded Adaptors Assemble Inlet Outlet ADAPTORS, or Single Bypass Valve Bypass Valve Clips Installing HoldingValve Bypass Bypass Valve Turned DownwardPosition Softener Into Place Connect the SoftenerIII Connect the Valve Drain HoseConnect Salt Tank Overflow Tubing House Main Water Shutoff Valves Leak TestConnecting Transformer Installgroundingclampbetween Thesoftenerinand OUT PipesWater Meter Jumper Wire Cold Water Pipe GroundingShows, refer to the Troubleshooting Section InstallcoversProgram the Timer Restart the Water HeaterHardness Number SET Presenttime of DAYSET Water Hardness Number SET Regeneration TimeSanitize the Water Softener Sanitize Your Water Softener AS FollowsRemoving Additives Addingsalttothe StoragetankWater Softening Salt with Iron Check List of STEP-BY-STEP Guides to Install Has Salt been added to Salt tank? Unit been sanitized? SeeExtrarecharge Recharge NOWCalifornia Efficiency Requirement Optional Settings Salt Efficiency12 / 24 Hour Clock Water Flow Through the Softener Kenmores Ultra Cleansing Feature Recharge Time Remaining and Valve Position IndicatorsError Code Program MemoryRegeneration Soft Water Service and RegenerationService Water Flow Through Softener Brining and Brine Rinse Water Flow Through Softener in BackwashElectronics Soft Water Service and Regeneration Automatic BypassWater Flow Through Softener Fast Rinse Salt Bridge Salt BridgeIron from Resin BED Keeping the Water Softener Clean Nozzle & VenturiCleaning Nozzle & Venturi Drain ALL Water from Softener Protect the Water Softener from FreezingCorrection ProblemcauseChecklist to Help YOU Save Money Inches Model 38356 Timer Code S Model 39356 Timer Code SBypass Valves Pressure Drop PSI vs. Flow Rate GPM Flow Rate GPMAlways Make These Initial Checks First Eration CheckManual Initiated Electronics Diagnostics Possible ProblemProcedure for Removing Error Code From Faceplate Code Most LikelyOther Information Troubleshooting Valve Position IndicatorsTimer PWA Replacement ModelManualadvanceregeneration Check Checks, and the manual initiated diagnosticsBrine Valve Float Setting Cycle Flow Rates Gallons PER MINAssembly Rotary Valve ServiceDisassembly To Relieve PressureFill Cycle Valve Service CycleWater Flow Through the Softener Brining and Brine Rinse CycleBackwash Cycle Valve Backwash CycleFast Rinse Cycle Fast Rinse CycleRating Decal Location Water Softener Complete Part Number Part DescriptionINLET-OUTLET Grounding Clamps Brine Valve Assembly 4212 Wear-Strip Seal Cross-Section View No. Number Part Description Your Home
Related manuals
Manual 48 pages 28.32 Kb