Kenmore 625.39356, 625.38356 owner manual Always Make These Initial Checks First, Eration Check

Page 35

WIRING SCHEMATIC

 

BACKOFTIMER

 

 

 

 

 

(PWA)

 

 

 

Transformer ?f

AC INPUT

MOTOR

 

 

 

 

 

 

 

 

 

 

 

valve

 

 

 

 

motor

 

 

 

 

 

 

 

gm

 

 

 

Turbine

 

 

 

 

 

Sensor

 

b,.

O ,_

NO

Position

 

 

O

NC

Switch

 

 

 

FACEPLATE

Keep this manual with your water softener. If repairs are needed, the service technician must have the informa-

tion on the following pages.

ALWAYS MAKE THESE INITIAL CHECKS FIRST

1.Does the time display show the correct time of day?

If display is blank, check power source to the sof- tener.

If time is flashing, power was off for over 6 hours. The softener resumes normal operation but regen- erations occur at the wrong time.

If an error code (Example: Err3) shows in the face-

plate display, go to AUTOMATIC ELECTRONIC DIAGNOSTICS.

2.Plumbing bypass valve(s) must be fully in service position.

3.The inlet and outlet pipes must connect to the softener inlet and outlet respectively.

4.Is the transformer plugged into a "live" grounded wall outlet, and the power cable fastened secure- ly to the controller?

FIG. 51

5.The valve drain hose must be free of kinks and sharp bends, and not elevated over 8 ft. above the floor.

. Is there salt in the storage tank?

7.Is the brine tubing connected? Brine tubing con- nects to nozzle venturi and brine valve assembly.

. Is the brine valve float set right?

9.Press the SELECT button two times to display the hardness setting.

Be sure it is the correct setting for the household's water supply. (Make a hardness test of the raw water and compare with the hardness setting. Also test a soft water sample to verify if a problem exists.) Press the SELECT button twice more to return to present time in the display.

If you do not find the problem after making initial checks, do the MANUAL INITIATED ELECTRONIC DIAGNOSTICS, and the MANUAL ADVANCE REGEN-

ERATION CHECK.

Questions? Call The Kenmore Water Line 1-800-426-9345

35

Image 35
Contents Save this Manual Repair or Parts ? Call toll freeDisclaimer of implied warranties limitation of remedies ONE Year Limited Warranty on Water SoftenerTEN Year Limited Warranty Against Leaks Questions? Page Small Parts InspectshipmentParts Descriptions Pipe Proper Order to Install Water Treating EquipmentPlan Your Installation Tools NeededValve Where to Install the Water SoftenerDraw Your Pipes Fittings Suggested Slab Foundation InstallationDip Adding a pressure reducing valve may reduce the flow Before Installing Checks & TestsInlet and Outlet Threaded Adaptors Assemble Inlet Outlet ADAPTORS, or Single Bypass ValveBypass Valve Bypass Valve Turned Downward Installing HoldingValve Bypass ClipsConnect the Softener Position Softener Into PlaceIII Connect the Valve Drain HoseConnect Salt Tank Overflow Tubing Leak Test House Main Water Shutoff ValvesCold Water Pipe Grounding Installgroundingclampbetween Thesoftenerinand OUT PipesWater Meter Jumper Wire Connecting TransformerRestart the Water Heater InstallcoversProgram the Timer Shows, refer to the Troubleshooting SectionSET Regeneration Time SET Presenttime of DAYSET Water Hardness Number Hardness NumberSanitize Your Water Softener AS Follows Sanitize the Water SoftenerRemoving Additives Addingsalttothe StoragetankWater Softening Salt with Iron Has Salt been added to Salt tank? Unit been sanitized? See Check List of STEP-BY-STEP Guides to InstallRecharge NOW ExtrarechargeCalifornia Efficiency Requirement Optional Settings Salt Efficiency12 / 24 Hour Clock Water Flow Through the Softener Program Memory Recharge Time Remaining and Valve Position IndicatorsError Code Kenmores Ultra Cleansing FeatureRegeneration Soft Water Service and RegenerationService Water Flow Through Softener in Backwash Water Flow Through Softener Brining and Brine RinseElectronics Soft Water Service and Regeneration Automatic BypassWater Flow Through Softener Fast Rinse Salt Bridge Salt BridgeIron from Resin BED Keeping the Water Softener Clean Nozzle & VenturiCleaning Nozzle & Venturi Protect the Water Softener from Freezing Drain ALL Water from Softener Correction Problemcause Checklist to Help YOU Save Money Inches Model 38356 Timer Code S Model 39356 Timer Code SBypass Valves Flow Rate GPM Pressure Drop PSI vs. Flow Rate GPMEration Check Always Make These Initial Checks FirstCode Most Likely Possible ProblemProcedure for Removing Error Code From Faceplate Manual Initiated Electronics DiagnosticsModel Troubleshooting Valve Position IndicatorsTimer PWA Replacement Other InformationCycle Flow Rates Gallons PER MIN Checks, and the manual initiated diagnosticsBrine Valve Float Setting Manualadvanceregeneration CheckTo Relieve Pressure Rotary Valve ServiceDisassembly AssemblyBrining and Brine Rinse Cycle Valve Service CycleWater Flow Through the Softener Fill CycleFast Rinse Cycle Valve Backwash CycleFast Rinse Cycle Backwash CycleRating Decal Location Part Number Part Description Water Softener CompleteINLET-OUTLET Grounding Clamps Brine Valve Assembly 4212 Wear-Strip Seal Cross-Section View No. Number Part Description Your Home