Pelco C1487M-D operation manual 177

Page 20

Table E. Switch Settings for SW2 - D-Type Control (continued)

Receiver Address

 

 

 

Switch Setting

 

 

 

 

SW2-1

SW2-2

SW2-3 SW2-4 SW2-5

SW2-6 SW2-7

SW2-8

 

 

 

 

 

 

 

 

 

177

ON

OFF

OFF

OFF

ON

ON

OFF

ON

178

OFF

ON

OFF

OFF

ON

ON

OFF

ON

179

ON

ON

OFF

OFF

ON

ON

OFF

ON

180

OFF

OFF

ON

OFF

ON

ON

OFF

ON

181

ON

OFF

ON

OFF

ON

ON

OFF

ON

182

OFF

ON

ON

OFF

ON

ON

OFF

ON

183

ON

ON

ON

OFF

ON

ON

OFF

ON

184

OFF

OFF

OFF

ON

ON

ON

OFF

ON

185

ON

OFF

OFF

ON

ON

ON

OFF

ON

186

OFF

ON

OFF

ON

ON

ON

OFF

ON

187

ON

ON

OFF

ON

ON

ON

OFF

ON

188

OFF

OFF

ON

ON

ON

ON

OFF

ON

189

ON

OFF

ON

ON

ON

ON

OFF

ON

190

OFF

ON

ON

ON

ON

ON

OFF

ON

191

ON

ON

ON

ON

ON

ON

OFF

ON

192

OFF

OFF

OFF

OFF

OFF

OFF

ON

ON

193

ON

OFF

OFF

OFF

OFF

OFF

ON

ON

194

OFF

ON

OFF

OFF

OFF

OFF

ON

ON

195

ON

ON

OFF

OFF

OFF

OFF

ON

ON

196

OFF

OFF

ON

OFF

OFF

OFF

ON

ON

197

ON

OFF

ON

OFF

OFF

OFF

ON

ON

198

OFF

ON

ON

OFF

OFF

OFF

ON

ON

199

ON

ON

ON

OFF

OFF

OFF

ON

ON

200

OFF

OFF

OFF

ON

OFF

OFF

ON

ON

201

ON

OFF

OFF

ON

OFF

OFF

ON

ON

202

OFF

ON

OFF

ON

OFF

OFF

ON

ON

203

ON

ON

OFF

ON

OFF

OFF

ON

ON

204

OFF

OFF

ON

ON

OFF

OFF

ON

ON

205

ON

OFF

ON

ON

OFF

OFF

ON

ON

206

OFF

ON

ON

ON

OFF

OFF

ON

ON

207

ON

ON

ON

ON

OFF

OFF

ON

ON

208

OFF

OFF

OFF

OFF

ON

OFF

ON

ON

209

ON

OFF

OFF

OFF

ON

OFF

ON

ON

210

OFF

ON

OFF

OFF

ON

OFF

ON

ON

211

ON

ON

OFF

OFF

ON

OFF

ON

ON

212

OFF

OFF

ON

OFF

ON

OFF

ON

ON

213

ON

OFF

ON

OFF

ON

OFF

ON

ON

214

OFF

ON

ON

OFF

ON

OFF

ON

ON

215

ON

ON

ON

OFF

ON

OFF

ON

ON

216

OFF

OFF

OFF

ON

ON

OFF

ON

ON

217

ON

OFF

OFF

ON

ON

OFF

ON

ON

218

OFF

ON

OFF

ON

ON

OFF

ON

ON

219

ON

ON

OFF

ON

ON

OFF

ON

ON

220

OFF

OFF

ON

ON

ON

OFF

ON

ON

221

ON

OFF

ON

ON

ON

OFF

ON

ON

222

OFF

ON

ON

ON

ON

OFF

ON

ON

223

ON

ON

ON

ON

ON

OFF

ON

ON

224

OFF

OFF

OFF

OFF

OFF

ON

ON

ON

225

ON

OFF

OFF

OFF

OFF

ON

ON

ON

226

OFF

ON

OFF

OFF

OFF

ON

ON

ON

227

ON

ON

OFF

OFF

OFF

ON

ON

ON

228

OFF

OFF

ON

OFF

OFF

ON

ON

ON

229

ON

OFF

ON

OFF

OFF

ON

ON

ON

230

OFF

ON

ON

OFF

OFF

ON

ON

ON

231

ON

ON

ON

OFF

OFF

ON

ON

ON

232

OFF

OFF

OFF

ON

OFF

ON

ON

ON

233

ON

OFF

OFF

ON

OFF

ON

ON

ON

234

OFF

ON

OFF

ON

OFF

ON

ON

ON

235

ON

ON

OFF

ON

OFF

ON

ON

ON

236

OFF

OFF

ON

ON

OFF

ON

ON

ON

 

 

 

 

 

 

 

 

 

Continued on next page

20

Pelco Manual C1487M-D (7/99)

Image 20
Contents Listed Contents List of Illustrations List of TablesMeasures DE Securite Importantes Important Safeguards and WarningsGeneral IN-CEILING Models Back BoxDome Drive Lower DomePendant Models Pendant ComponentsDescription ModelsSpectra II Pendant Components Spectra II IN-CEILING ComponentsInstallation for IN-CEILING Models Spectra Lite Pendant ComponentsSpectra Lite IN-CEILING Components Ceiling and Back BOX PreparationInstalling Back Box Suspended CeilingWiring Wiring Diagram for SpectraCable Type Maximum Distance RG6/UBack BOX Installation Table B VAC Wiring DistancesFrom controller To 4-Wire terminal on circuit board Back BOX ConnectionsSpectra II Only The maxi Switch Locations Table C. Switch Settings for SW1 Dome DriveBaud Rate Switch Setting SW2-6 SW2-7 SW2-8 For D-type control systems, refer to Table EFor P-type control systems, refer to Table D 100 117 177 Lower Dome Installation, In-Ceiling Models Lower DomeInstallation for Pendant Models PENDANT-MOUNT InstallationSURFACE-MOUNT Installation OperationPOWER-UP Display PAN and Tilt FunctionsAuto Flip Scan SpeedPreset Functions ZoomSpectra II Zoom Spectra Lite ZoomAlarms RANDOM, FRAME, and Auto ScanningZones PatternsAuxiliary Outputs ParkProgramming the Spectra II and Spectra Lite White bal hue Spectra Lite only Prev to first camera submenuMain Menu Access Backlight CompensationDenotes items that apply to the Spectra II only Reset CameraZoom Limit AGC Mode GAIN/AGCGain Auto IrisShutter Speed AUTO-FOCUS Mode SharpnessWhite Balance Color Cameras only Line SynchronizationPOWER-UP Mode AUX Mode Alarm ResumeAlarm Dwell Alarm PriorityAlarm Pattern Zone BlankProportional PAN Limit Stops Turning Limit Stops On or OffPark Time Minutes Pattern LengthTroubleshooting Symptom Unit does not operateSymptom Fan does not operate Symptom Alarms not going to presetSymptom Alarms not starting a pattern Symptom Motion problemsDome Cleaning MaintenanceBack BOX Electronic Assembly Removal Specifications MechanicalSD5 Series Dimension Drawing Ntsc EIA Warranty and Return Information Regulatory Notices