Pelco C1487M-D operation manual Auxiliary Outputs, Park

Page 27

In certain situations, the dome will respond as follows:

If a preset has not been set, but an alarm is connected: the dome will go to a factory preset that will not be the desired position.

If one alarm is a preset and another is a pattern and both are received: the dome will alternate between them.

An alarm clears by returning to its former (off) state.

Depending on choices made on the programming menu, the dome can respond to an alarm by running one of the patterns below. (Refer to the Patterns section for more information.)

Run full pattern

Run half pattern 1

Run half pattern 2

When sequencing between presets, the dwell time depends on the time set on the Alarm Dwell submenu for that preset. After the dwell time expires, the dome immediately does one of the following:

If the resume feature was selected on the programming menu and there are no other alarms activated, the dome resumes its prior activity. So, it might return to its previous position or resume a scan or pattern.

If there are other alarms activated, the dome goes to them.

If you move the joystick to pan or tilt the dome, or if you issue a lens command while there is an alarm, the pan and tilt or lens command overrides the alarm. Sixty seconds after the last pan and tilt or lens command, the dome will return to the alarm preset if the alarm is still active.

AUXILIARY OUTPUTS

(This section applies to Spectra II™ only.)

An AUX 1 command from the controller will activate the relay in the dome and operate the device that is connected to the relay. The relay will remain latched until a clear command is issued.

An AUX 2 command from the controller will place a ground at the output of AUX 2 to operate the device that is connected to it. The output will remain latched until a clear command is issued. Refer to the Back Box Connections section for precautions regarding the use of the AUX 2 output.

The output relay can also be programmed so that it is activated when any alarm input is activated. When latching (toggling) is selected on the programming menu, giving the AUX 1 command from the controller changes the state of the AUX (for example, if it was on, this turns it off.) The clear command from the controller will turn the AUX off in the latching or toggle mode.

PARK

If the dome does not receive any commands for a specified period of time (refer to the Park Time Minutes section), the dome will go to preset 1 and park. If the time specified is zero, or if preset 1 has not been programmed, the dome will not park. The default is zero minutes.

Pelco Manual C1487M-D (7/99)

27

Image 27
Contents Listed Contents List of Tables List of IllustrationsImportant Safeguards and Warnings GeneralMeasures DE Securite Importantes Lower Dome IN-CEILING ModelsBack Box Dome DrivePendant Components Pendant ModelsSpectra II IN-CEILING Components DescriptionModels Spectra II Pendant ComponentsCeiling and Back BOX Preparation Installation for IN-CEILING ModelsSpectra Lite Pendant Components Spectra Lite IN-CEILING ComponentsSuspended Ceiling Installing Back BoxWiring Diagram for Spectra WiringRG6/U Cable Type Maximum DistanceTable B VAC Wiring Distances Back BOX InstallationBack BOX Connections From controller To 4-Wire terminal on circuit boardSpectra II Only The maxi Dome Drive Switch Locations Table C. Switch Settings for SW1For D-type control systems, refer to Table E Baud Rate Switch Setting SW2-6 SW2-7 SW2-8For P-type control systems, refer to Table D 100 117 177 Lower Dome Lower Dome Installation, In-Ceiling ModelsPENDANT-MOUNT Installation Installation for Pendant ModelsOperation SURFACE-MOUNT InstallationScan Speed POWER-UP DisplayPAN and Tilt Functions Auto FlipSpectra Lite Zoom Preset FunctionsZoom Spectra II ZoomPatterns AlarmsRANDOM, FRAME, and Auto Scanning ZonesPark Auxiliary OutputsWhite bal hue Spectra Lite only Prev to first camera submenu Programming the Spectra II and Spectra LiteBacklight Compensation Main Menu AccessReset Camera Zoom LimitDenotes items that apply to the Spectra II only GAIN/AGC AGC ModeAuto Iris GainShutter Speed Sharpness AUTO-FOCUS ModeLine Synchronization White Balance Color Cameras onlyPOWER-UP Mode Alarm Resume AUX ModeAlarm Priority Alarm DwellZone Blank Alarm PatternProportional PAN Turning Limit Stops On or Off Limit StopsPattern Length Park Time MinutesSymptom Unit does not operate TroubleshootingSymptom Motion problems Symptom Fan does not operateSymptom Alarms not going to preset Symptom Alarms not starting a patternMaintenance Back BOX Electronic Assembly RemovalDome Cleaning Mechanical SpecificationsSD5 Series Dimension Drawing Ntsc EIA Regulatory Notices Warranty and Return Information