Pelco C1487M-D operation manual Specifications, Mechanical

Page 46

SPECIFICATIONS

MECHANICAL

 

Construction

 

Back box:

Aluminum

Dome drive:

Aluminum, ABS plastic

Lower dome:

Acrylic

Cable Entry

 

In-Ceiling:

.75" (1.91 cm) conduit fitting

Pendant:

Through 1.5" (3.81 cm) NPT pendant mount

Pan Movement:

360° Continuous pan rotation

Vertical Tilt:

Unobstructed +2° to -92°

Manual Pan/Tilt

 

Speeds*

0.5°-80°/sec manual operation, 150°/sec turbo

Pan:

Tilt:

0.5°-40°/sec

Preset Speeds

250°/sec

Pan:

Tilt

200°/sec

*For variable-speed operation an appropriate controller is required. With fixed-speed controllers, Spectra II™ and Spectra Lite™ pan speed is 30°/sec and tilt speed is 12°/ sec. The CM6700 controller with the KBD200 keyboard has programmable fixed speeds.

ELECTRICAL

Input Voltage:

18-30 VAC, 24 VAC nominal

Input Power

In-ceiling: 30 vA

Indoor pendant: 30 vA

Outdoor pendant: 75 vA

Fuse:

1.6 A

 

Relay Contacts

AUX 1

AUX 2 Output

Type:

Form C

Open collector transistor output

Voltage:

Low voltage (<40 V)

32 VDC maximum

Current:

2 A maximum

150 mA maximum

GENERAL

Environment

In-Ceiling: Indoor only

Pendant: Indoor/outdoor

Operating Range

In-Ceiling: 32° to 140°F (0° to 60°C) intermittent operation; 32° to 122°F (0° to 50°C) continuous operation

Pendant

Without Heater: 32° to 140°F (0° to 60°C) absolute maximum operating temperature; 32° to 122°F (0° to 50°C) sustained maximum operating temperature

With Heater*: (Assumes no wind chill factor; for detailed test conditions, contact Pelco.) Maximum operating temperature: 140°F (60°C) absolute maximum; 122°F (50°C) sustained maximum

Minimum operating temperature: -60°F (-51.11°C) absolute minimum; minimal icing at -50°F (-45.56°C) sustained minimum; prevents icing at -40°F (-40°C) sustained minimum; de-ices .1 inch (2.5 mm) within 3 hours after power-up

Dimensions:

See Figure 18

46

Pelco Manual C1487M-D (7/99)

Image 46
Contents Listed Contents List of Illustrations List of TablesGeneral Important Safeguards and WarningsMeasures DE Securite Importantes Dome Drive IN-CEILING ModelsBack Box Lower DomePendant Models Pendant ComponentsSpectra II Pendant Components DescriptionModels Spectra II IN-CEILING ComponentsSpectra Lite IN-CEILING Components Installation for IN-CEILING ModelsSpectra Lite Pendant Components Ceiling and Back BOX PreparationInstalling Back Box Suspended CeilingWiring Wiring Diagram for SpectraCable Type Maximum Distance RG6/UBack BOX Installation Table B VAC Wiring DistancesFrom controller To 4-Wire terminal on circuit board Back BOX ConnectionsSpectra II Only The maxi Switch Locations Table C. Switch Settings for SW1 Dome DriveBaud Rate Switch Setting SW2-6 SW2-7 SW2-8 For D-type control systems, refer to Table EFor P-type control systems, refer to Table D 100 117 177 Lower Dome Installation, In-Ceiling Models Lower DomeInstallation for Pendant Models PENDANT-MOUNT InstallationSURFACE-MOUNT Installation OperationAuto Flip POWER-UP DisplayPAN and Tilt Functions Scan SpeedSpectra II Zoom Preset FunctionsZoom Spectra Lite ZoomZones AlarmsRANDOM, FRAME, and Auto Scanning PatternsAuxiliary Outputs ParkProgramming the Spectra II and Spectra Lite White bal hue Spectra Lite only Prev to first camera submenuMain Menu Access Backlight CompensationZoom Limit Reset CameraDenotes items that apply to the Spectra II only AGC Mode GAIN/AGCGain Auto IrisShutter Speed AUTO-FOCUS Mode SharpnessWhite Balance Color Cameras only Line SynchronizationPOWER-UP Mode AUX Mode Alarm ResumeAlarm Dwell Alarm PriorityAlarm Pattern Zone BlankProportional PAN Limit Stops Turning Limit Stops On or OffPark Time Minutes Pattern LengthTroubleshooting Symptom Unit does not operateSymptom Alarms not starting a pattern Symptom Fan does not operateSymptom Alarms not going to preset Symptom Motion problemsBack BOX Electronic Assembly Removal MaintenanceDome Cleaning Specifications MechanicalSD5 Series Dimension Drawing Ntsc EIA Warranty and Return Information Regulatory Notices