INSTALLATION FOR PENDANT MODELS
PENDANT-MOUNT INSTALLATION
NOTE: If outdoors, apply Duct Seal inside the pipe portion of the back box to prevent moisture or cold air inside the mount from enter- ing the unit and causing condensation on the dome. Make sure no moisture has condensed inside the unit before installing the lower dome. Duct Seal can be purchased through local electrical supply houses.
1.Install the pendant dome mount. Refer to the instructions supplied with the mount. If the mount is outdoors, make sure it is properly sealed to keep moisture out.
2.Bring the wiring for the dome through the mount. Refer to the Wiring section.
3.Refer to Figure 10. Loosen the thumbscrew inside the back box and open the hinged door.
4.Screw the back box into the mount and bring the wiring into the back box. If outdoors, apply the provided pipe sealant to the threads on the back box.
5.Attach the wiring to the back box. Refer to the Back Box Connections section.
6.Install the dome drive. Refer to the Dome Drive section.
7.Remove the
8.Refer to Figure 16. Hanging down from the back box is a short cable (the trim ring leash). Hold up the lower dome near the back box so that the trim ring leash touches the lower dome. Line up the two screw holes in the trim ring of the lower dome with the two screw holes in the back box. Place a finger on the edge of the trim ring where the leash touches the lower dome.
9.Look inside the lower dome and note which of the six retainer screws is closest to your finger. Remove this screw and attach the trim ring leash to the screw. Reinstall the screw securely and make sure the leash will hold the lower dome.
LEASH
SCREW HOLES
(FRONT & BACK)
ATTACH LEASH
TO NEAREST
RETAINER
SCREW
Figure 16. Lower Dome Installation, Pendant Models
22 | Pelco Manual |