Pelco C1487M-D operation manual Programming the Spectra II and Spectra Lite

Page 28

PROGRAMMING THE SPECTRA II™ AND SPECTRA LITE™

The Spectra II™ and Spectra Lite™ domes can be programmed for the following functions.

(In this section, an asterisk denotes items that apply to Spectra II only.)

AGC (automatic gain control)

Auto park time

Power-up mode

Alarm dwell*

Auxiliary relays*

Proportional panning*

Alarm pattern*

Backlight compensation

Scan speed

Alarm priority*

Camera reset

Sharpness

Alarm resume*

Gain

Shutter speed

Auto flip disable

Limit stops

Video zone blanking*

Auto focus

Pattern length*

White balance

Auto iris

Power line synchronization

Zoom limit*

The main menu contains six secondary menus for Spectra II™ and four for Spectra Lite™.

Camera

Aux*

Line Sync

Alarms, Zone Blank*

Power Up Mode

Other

Each secondary menu has submenus, which are structured as shown below.

1.Camera

First Camera Submenu Backlight comp Zoom limit*

Reset camera Gain/AGC

AGC mode Gain

Auto-iris Auto-iris mode Auto-iris level Auto-iris peak*

Next (to second camera submenu)

2.Line Sync

Line sync

Line sync phase

3.Power Up Power Up

4.Aux*

Aux 1 mode*

Aux 2 mode*

5.Alarm, Zone Blank* Alarm resume* Alarm dwell sec* Alarm priority* Alarm pattern* Zone blank*

6.Other

Auto flip

Proportional pan*

Limit stops

Park time minutes

Scan speed deg/s

Pattern length*

Second Camera Submenu

Shutter speed

Auto focus mode Sharpness

Auto sharpness* Sharpness

White balance Auto white bal R-B white bal* M-G white bal*

White bal hue (Spectra Lite™ only) Prev (to first camera submenu)

The following sections explain how to program the Spectra II™ and Spectra Lite™ domes using the menu choices.

28

Pelco Manual C1487M-D (7/99)

Image 28
Contents Listed Contents List of Illustrations List of TablesGeneral Important Safeguards and WarningsMeasures DE Securite Importantes IN-CEILING Models Back BoxDome Drive Lower DomePendant Models Pendant ComponentsDescription ModelsSpectra II Pendant Components Spectra II IN-CEILING ComponentsInstallation for IN-CEILING Models Spectra Lite Pendant ComponentsSpectra Lite IN-CEILING Components Ceiling and Back BOX PreparationInstalling Back Box Suspended CeilingWiring Wiring Diagram for SpectraCable Type Maximum Distance RG6/UBack BOX Installation Table B VAC Wiring DistancesFrom controller To 4-Wire terminal on circuit board Back BOX ConnectionsSpectra II Only The maxi Switch Locations Table C. Switch Settings for SW1 Dome DriveBaud Rate Switch Setting SW2-6 SW2-7 SW2-8 For D-type control systems, refer to Table EFor P-type control systems, refer to Table D 100 117 177 Lower Dome Installation, In-Ceiling Models Lower DomeInstallation for Pendant Models PENDANT-MOUNT InstallationSURFACE-MOUNT Installation OperationPOWER-UP Display PAN and Tilt FunctionsAuto Flip Scan SpeedPreset Functions ZoomSpectra II Zoom Spectra Lite ZoomAlarms RANDOM, FRAME, and Auto ScanningZones PatternsAuxiliary Outputs ParkProgramming the Spectra II and Spectra Lite White bal hue Spectra Lite only Prev to first camera submenuMain Menu Access Backlight CompensationZoom Limit Reset CameraDenotes items that apply to the Spectra II only AGC Mode GAIN/AGCGain Auto IrisShutter Speed AUTO-FOCUS Mode SharpnessWhite Balance Color Cameras only Line SynchronizationPOWER-UP Mode AUX Mode Alarm ResumeAlarm Dwell Alarm PriorityAlarm Pattern Zone BlankProportional PAN Limit Stops Turning Limit Stops On or OffPark Time Minutes Pattern LengthTroubleshooting Symptom Unit does not operateSymptom Fan does not operate Symptom Alarms not going to presetSymptom Alarms not starting a pattern Symptom Motion problemsBack BOX Electronic Assembly Removal MaintenanceDome Cleaning Specifications MechanicalSD5 Series Dimension Drawing Ntsc EIA Warranty and Return Information Regulatory Notices