Specifications

 

 

 

 

 

 

 

 

 

Table 1. Specifications

 

 

Model

GBC

 

 

Input Voltage

90-130, 170-240 VAC

 

 

Max. Current

9.3 A @ 120 V

 

 

Frequency

50-60 Hz Single-Phase

 

 

Lamp Type

1,000 Watt Metal Halide

 

 

Total Luminous Flux

99,750 lm

 

 

Standard Balloon Diameter

47.2 in (1200 mm)

 

 

Light Coverage (360°)

150 ft (45.7 meters)

 

 

Lamp Surface Temperature (Longitudinal)

476.6° F (247° C) max

 

 

Lamp Surface Temperature (Transversal)

417.2° F (214° C) max

 

 

Balloon Dimensions (L x W x H)

47.2 x 47.2 x 28.3 in.

 

 

(1200 x 1200 x 720 mm)

 

 

 

 

 

Balloon Material

Polyester

 

 

Balloon Heat-Resisting Temperature

320-356° F (160-180° C)

 

 

Internal Balloon Temperature

126° F (52° C)

 

 

Balloon Water Resistance

1,500 mm H2O

 

 

Fan Motor Voltage

24 VDC

 

 

Fan Motor Current

1.2 A

 

 

Fan Motor Pressure

0.324 kPA (0.047 psi)

 

 

Outriggers

3

 

 

Mast - Number of Stages

3 (air shock absorbers)

 

 

Dimensions (L x W x H)

51.2 x 52.2 x 73.6 to 126 in

 

 

Upper Working Position

(1,300 x 1,325 x 1,870 to 3,200 mm)

 

 

Dimensions (L x W x H)

27.6 x 40 x 47.7 in

 

 

Storage

(700 x 1,023 x 1,212 mm)

 

 

Weight

133.4 lb (49.8 kg)

 

 

Appropriate Generator

1700 Watts

 

page 12 — GBC lighting system • operation and parts manual — rev. #0 (06/24/13)

Image 12
Contents Model GBC This Manual Must Accompany the Equipment AT ALL TimesPage Page Fuel Chemical Warning Table of Contents GBC Lighting SystemChoose from three easy options Safety Information SaFety messagesSaFety symBols General saFety Lighting system saFety Lamp saFety never attempt service on a running machine  never unplug the lamp’s AC power cable during operationBalloon saFety Generator saFetyEleCtriCal saFety Power Cord/Cable safetyTransporting saFety Cart type no lifiting hookSpecifications Dimensions DimensionsFootcandle plot Illumination RangeGeneral information 230V 50 Ft 100 Ft 200 Ft 300 Ft 400 Ft 500 Ft 600 Ft 800 FtComponents GBC ComponentsAC Power Cable Connects to the AC power source Setup Fold the balloon cover into itself and zip it up. See FigureSecuring Cable with Hook Operation Applying Parking BrakeReleasing Parking Brake Deploying outriggerStowing Outrigger Raising the mastApplying Power Lowering the MastDimming the Lamp Start the generator as indicated in the generator manualTurn off the power switch of the generator Disconnect the lamp connector from the AC power cableShutdown StorageMaintenance Replacing LampRemove the lamp guard Figure Replacing Balloon Unzip the top and bottom of the balloon. See FigureZip up the top and bottom of the new balloon. See Figure Filter replacement Locking Air PlateLoose? Lamp does not lightUnplug all other appliances Wait for lamp to cool downC11 C10 C5 C8 Adjust Link for front shaft Spray grease Brake Not working properly? AdjustPower cable Defective or worn cable? Replace Plug Lamp Base Lamp base loose? Screw in securelyWiring diagram Page Explanation of Code in Remarks Column Suggested Spare Parts GBC lIGHTING System 1 to 3 unitsNameplate and decals A400324800 A400324500A400324000 A400324600Balloon and lamp assy Part Name QTY Remarks Mast assy A300175400 A300175500A300175600 A400199700Base assy A100064700 A300147201A300147301 A300056800Outrigger assy A300162202 1641001430A400175302 A400176901Terms and Conditions of Sale Parts Freight poliCyPage HERE’S HOW to GET Help