Multiquip GBC Lamp Base Lamp base loose? Screw in securely, Tighten securely Brake pedal, Stopper

Page 29

maintenance

Table 5. Periodic Check and Maintenance

FIGURE

 

 

PART

 

CHECK ITEM

 

SOLUTION

 

 

 

 

L1

Lamp (Base)

Lamp base loose?

Screw in securely.

 

Lamp

 

L2

Lamp Holder

Lamp holder loose?

Replace.

 

#

 

L3

Pipe Frame

Pipe Frame skewed?

Replace.

 

&

 

 

 

 

 

L4

Lamp

Defective lamp?

Replace.

 

 

 

B1

Balloon (Envelope)

Defective or dirty?

Replace.

 

Balloon

 

B2

Zipper

Broken?

 

Replace.

 

 

B3

Fan Motor (Blower)

Not working properly?

Repair or replace.

 

$

 

 

 

 

 

B4

T-handle bolt (balloon)

Broken?

 

Replace.

 

 

 

C1

Outrigger

Movement not smooth?

Spray grease.

 

$

 

 

C2

T-handle and wheels

Improper movement?

Tighten securely.

 

$

 

 

C3

Bolt for handle

Bolt loose?

 

Tighten securely.

 

$

 

 

C4

Brake pedal

Linkage not working correctly?

Check, spray grease.

 

 

 

Notch worn-out?

Replace.

 

 

 

 

 

 

 

Cart

 

C5

Stopper

Damaged?

 

Replace.

 

#

 

C6

Front wheel pivot

Does not turn smoothly?

Check, spray grease.

 

$

 

 

 

 

 

C7

Tires

Tire pressure not 35.5 psi (294 kPa)?

Adjust.

 

 

 

C8

Link for front shaft

Linkage not working correctly?

Spray grease.

 

$

 

 

C9

Brake

Not working properly?

Adjust.

 

 

 

C10

Lever

Lever loose?

Tighten securely.

 

 

 

C11

Counterweight (Outrigger)

Does not work smoothly?

Spray grease.

 

Electric

 

E1

Power cable

Defective or worn cable?

Replace.

 

 

E2

Plug

Damaged?

 

Replace.

 

#

 

 

 

 

• — Check daily

 

# — Every 20 hours

 

$ — Every 100 hours

 

& — Every 500 hours

 

gbc lighting system • operation and parts manual —rev. #0 (06/24/13) — page 29

Image 29
Contents This Manual Must Accompany the Equipment AT ALL Times Model GBCPage Page Fuel Chemical Warning GBC Lighting System Table of ContentsChoose from three easy options SaFety symBols Safety InformationSaFety messages General saFety Lamp saFety Lighting system saFety never attempt service on a running machine  never unplug the lamp’s AC power cable during operationGenerator saFety Balloon saFetyEleCtriCal saFety Power Cord/Cable safetyCart type no lifiting hook Transporting saFetySpecifications Dimensions DimensionsIllumination Range Footcandle plot230V 50 Ft 100 Ft 200 Ft 300 Ft 400 Ft 500 Ft 600 Ft 800 Ft General informationGBC Components ComponentsAC Power Cable Connects to the AC power source Fold the balloon cover into itself and zip it up. See Figure SetupSecuring Cable with Hook Applying Parking Brake OperationReleasing Parking Brake Deploying outriggerRaising the mast Stowing OutriggerLowering the Mast Applying PowerDimming the Lamp Start the generator as indicated in the generator manualDisconnect the lamp connector from the AC power cable Turn off the power switch of the generatorShutdown StorageRemove the lamp guard Figure MaintenanceReplacing Lamp Zip up the top and bottom of the new balloon. See Figure Replacing BalloonUnzip the top and bottom of the balloon. See Figure Locking Air Plate Filter replacementLamp does not light Loose?Unplug all other appliances Wait for lamp to cool downC11 C10 C5 C8 Spray grease Brake Not working properly? Adjust Adjust Link for front shaftPower cable Defective or worn cable? Replace Plug Lamp Base Lamp base loose? Screw in securelyWiring diagram Page Explanation of Code in Remarks Column GBC lIGHTING System 1 to 3 units Suggested Spare PartsNameplate and decals A400324500 A400324800A400324000 A400324600Balloon and lamp assy Part Name QTY Remarks Mast assy A300175500 A300175400A300175600 A400199700Base assy A300147201 A100064700A300147301 A300056800Outrigger assy 1641001430 A300162202A400175302 A400176901Freight poliCy Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help