Multiquip GBC manual Maintenance, Replacing Lamp, Remove the lamp guard Figure

Page 24

maintenance

REPLACING LAMP

DANGER

Never attempt to replace lamp in a wet place. The possibility exists of electric shock.

WARNING

Always allow sufficient time for the lamp to cool down before replacing.The possibility exists of severe burns if hot lamp is touched.

\ CAUTION

Always shutdown power source and remove balloon assembly from mast when replacing a broken lamp. Utmost care should be taken in handling broken lamp. The possibility exists of serious injury from handling a broken lamp.

1.Unzip the zipper at the bottom of the balloon and roll the balloon up to expose the lamp. See Figure 26.

BALLOON

ENVELOPE

ZIPPER

Figure 26. Exposing Balloon

2. Release the lamp guard locking tabs. See Figure 27.

LOCK

TAB

LAMP

GUARD

LOCK

TAB

Figure 27. Removing Lamp Guard

3. Remove the lamp guard (Figure 28).

LAMP

HOLDER

LAMP

GUARD

Figure 28. Lamp Guard Removal

4.Press tabs on the lamp holder and lift up holder to release lamp. Remove the lamp from the lamp socket by turning lamp counterclockwise. See Figure 29.

LAMP

SOCKET

Figure 29. Removing Lamp

5.Install new lamp into socket and turn lamp in a clockwise direction until tight. See Figure 30. Press tabs on the lamp holder and slowly bring down the holder to secure lamp in place.

LAMP

SOCKET

Figure 30. Installing New Lamp

page 24 — GBC lighting system • operation and parts manual — rev. #0 (06/24/13)

Image 24
Contents Model GBC This Manual Must Accompany the Equipment AT ALL TimesPage Page Fuel Chemical Warning Table of Contents GBC Lighting SystemChoose from three easy options Safety Information SaFety messagesSaFety symBols General saFety Lighting system saFety Lamp saFety never attempt service on a running machine  never unplug the lamp’s AC power cable during operationBalloon saFety Generator saFetyEleCtriCal saFety Power Cord/Cable safetyTransporting saFety Cart type no lifiting hookSpecifications Dimensions DimensionsFootcandle plot Illumination RangeGeneral information 230V 50 Ft 100 Ft 200 Ft 300 Ft 400 Ft 500 Ft 600 Ft 800 FtComponents GBC ComponentsAC Power Cable Connects to the AC power source Setup Fold the balloon cover into itself and zip it up. See FigureSecuring Cable with Hook Operation Applying Parking BrakeReleasing Parking Brake Deploying outriggerStowing Outrigger Raising the mastApplying Power Lowering the MastDimming the Lamp Start the generator as indicated in the generator manualTurn off the power switch of the generator Disconnect the lamp connector from the AC power cableShutdown StorageMaintenance Replacing LampRemove the lamp guard Figure Replacing Balloon Unzip the top and bottom of the balloon. See FigureZip up the top and bottom of the new balloon. See Figure Filter replacement Locking Air PlateLoose? Lamp does not lightUnplug all other appliances Wait for lamp to cool downC11 C10 C5 C8 Adjust Link for front shaft Spray grease Brake Not working properly? AdjustPower cable Defective or worn cable? Replace Plug Lamp Base Lamp base loose? Screw in securelyWiring diagram Page Explanation of Code in Remarks Column Suggested Spare Parts GBC lIGHTING System 1 to 3 unitsNameplate and decals A400324800 A400324500A400324000 A400324600Balloon and lamp assy Part Name QTY Remarks Mast assy A300175400 A300175500A300175600 A400199700Base assy A100064700 A300147201A300147301 A300056800Outrigger assy A300162202 1641001430A400175302 A400176901Terms and Conditions of Sale Parts Freight poliCyPage HERE’S HOW to GET Help