Multiquip GBC manual Loose?, Lamp does not light, Unplug all other appliances

Page 27

 

 

maintenance

 

 

 

 

 

 

 

Table 4. Troubleshooting

 

SYMPTOM

POSSIBLE PROBLEM

SOLUTION

 

Is plug disconnected?

Plug in correctly.

 

Is generator power switched off?

Turn on switch.

 

Is lamp loose?

Screw lamp securely into socket.

 

Is power connector disconnected or

Connect disconnected connector.

 

loose?

 

 

Lamp does not light.

Are any other electric appliances

 

(other than light tower) plugged into

Unplug all other appliances.

 

 

power source?

 

 

Is model of lamp incompatible?

Use genuine MQ lamp.

 

Is lamp not cool enough to light

 

 

again? (Interval of 5 to 10 minutes

Wait for lamp to cool down.

 

is required before turning on lamp

 

 

 

again)

 

Lamp only lights for a short time.

Is ambient temperature too high

Move lamp where there is proper

(more than 104° F (40° C)?

ventilation.

 

 

Is fan motor (blower) not working

Check and repair fan motor (blower).

Balloon does not inflate.

properly?

 

 

Is balloon envelope defective?

Repair or replace balloon envelope.

gbc lighting system • operation and parts manual —rev. #0 (06/24/13) — page 27

Image 27
Contents This Manual Must Accompany the Equipment AT ALL Times Model GBCPage Page Fuel Chemical Warning GBC Lighting System Table of ContentsChoose from three easy options Safety Information SaFety messagesSaFety symBols General saFety  never unplug the lamp’s AC power cable during operation Lighting system saFetyLamp saFety  never attempt service on a running machinePower Cord/Cable safety Balloon saFetyGenerator saFety EleCtriCal saFetyCart type no lifiting hook Transporting saFetySpecifications Dimensions DimensionsIllumination Range Footcandle plot230V 50 Ft 100 Ft 200 Ft 300 Ft 400 Ft 500 Ft 600 Ft 800 Ft General informationGBC Components ComponentsAC Power Cable Connects to the AC power source Fold the balloon cover into itself and zip it up. See Figure SetupSecuring Cable with Hook Deploying outrigger OperationApplying Parking Brake Releasing Parking BrakeRaising the mast Stowing OutriggerStart the generator as indicated in the generator manual Applying PowerLowering the Mast Dimming the LampStorage Turn off the power switch of the generatorDisconnect the lamp connector from the AC power cable ShutdownMaintenance Replacing LampRemove the lamp guard Figure Replacing Balloon Unzip the top and bottom of the balloon. See FigureZip up the top and bottom of the new balloon. See Figure Locking Air Plate Filter replacementWait for lamp to cool down Loose?Lamp does not light Unplug all other appliancesC11 C10 C5 C8 Lamp Base Lamp base loose? Screw in securely Adjust Link for front shaftSpray grease Brake Not working properly? Adjust Power cable Defective or worn cable? Replace PlugWiring diagram Page Explanation of Code in Remarks Column GBC lIGHTING System 1 to 3 units Suggested Spare PartsNameplate and decals A400324600 A400324800A400324500 A400324000Balloon and lamp assy Part Name QTY Remarks Mast assy A400199700 A300175400A300175500 A300175600Base assy A300056800 A100064700A300147201 A300147301Outrigger assy A400176901 A3001622021641001430 A400175302Freight poliCy Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help