Mounting | Average Temperature/Water Bottom Sensor and Converter |
|
|
5.2.2Thermo well method
The flexible tube is inserted into a thermo well with a diameter of 2" or more.
If the tank internal pressure exceeds 1bar, fix the thermo well in accordance with below figure.
welding
From tank bottom to element position #1 approx.500 mm(20")
Tank bottom
Electrical compartment
Cable entry as specified
Flange
Flexible tube
Ø26 mm(1.02")
Clearance below bottom hook
400 mm (15.57")
Figure 5-5: Thermo well application
Caution! The flexible tube must be lowered carefully without bending too much or scratching at the inner edge of the nozzle hole.
1.Insert a gasket and lower the flexible tube into the inlet of the stilling well.
2.Rotate the 4532 ATC so that you can set up the cable in the most convenient way.
3.Fix the mounting flange of the 4532 ATC to the nozzle on the tank top using bolts.