Varec 4532 manual Disclaimer of Warranties

Page 4

Average Temperature/Water Bottom Sensor and Converter

Disclaimer of Warranties

The contract between the Seller and the Buyer states the entire obligation of the Seller. The contents of this document shall not become part of or modify any prior or existing agreement, commitment or relationship between the Seller and Buyer. There are no express or implied warranties set out in this document. The only warranties that apply are those in the existing contract between the Seller and Buyer.

Varec, Inc. products have not been tested by Varec, Inc. under all possible operational conditions, and Varec, Inc. may not have all the data relative to your application. The information in this document is not all inclusive and does not and cannot take into account all unique situations. Consequently, the user should review this product literature in view of his/her application. If you have any further questions, please contact Varec, Inc. for assistance.

Limitations of Seller's Liability

In the event that a court holds that this document created some new warranties, Seller's liability shall be limited to repair or replacement under the standard warranty clause. In no case shall the Seller's liability exceed that stated as Limitations of Remedy in the contract between the Seller and Buyer.

Terms of Use

The information provided in this document is provided “as is” without warranty of any kind. Varec, Inc. disclaim all warranties, either express or implied, including the warranties of merchantability and fitness for a particular purpose. In no event shall Varec, Inc. or its suppliers be liable for any damages whatsoever including direct, indirect, incidental, consequential, loss of business profits or special damages, even if Varec, Inc. or its suppliers have been advised of the possibility of such damages.

Use of parts that are not manufactured or supplied by Varec, Inc. voids any Varec, Inc. warranty and relieves Varec, Inc. of any obligation to service the product under warranty. Varec, Inc. recommends the use of only Varec, Inc. manufactured or supplied parts to maintain or service Varec, Inc. products.

Use of parts that are not manufactured or supplied by Varec, Inc. invalidates the agency approval for this product.

2

Installation and Operations Manual

Image 4
Contents Installation Page Copyright Disclaimer of Warranties Safety Precaution Definitions Safety Precautions Average Temperature/Water Bottom Sensor and Converter Contents Operation and Description of Instrument Function Index Varec, Inc Contents Installation and operation overview IntroductionIntroduction Software historySystem functional diagram HartSafety instructions Power supply WiringGrounding ReturnDirect voltage Safety instructions Device designation Nameplate IdentificationScope of delivery CE marks, declaration of conformity Installation Design, dimensionsRecommended procedure Incorrect procedure Flexible tube UnpackingInstallation Instructions Special conditions for safe useInstallation Mounting Mounting instructionMounting on a fixed roof tank Top anchor methodTensioning wire mounting Thermo well method Thermo well applicationAnchor weight method Flexible tube is stabilized by an anchor weightAnchor weight mounting Mounting on a floating roof tank Thermo well method Guide ring and anchor weight method 10Guide ring and anchor weight applicationMounting Wiring Terminal Connection 1 4532 ATC terminal2 6000 Series Servo Tank Gauge terminal 3 4590 TSM i.s. terminal4532 ATC Grounding Wiring Device set up 4590 TSM OperatingLocal Hart connection As a Varec tank gauging instrument As a standalone generic Hart instrument4532 ATC specific parameter set up on the 4590 TSM Device set up 6000 Series Servo Tank Gauge2 4532 ATC configuration on 6000 Series Servo Tank Gauge Preparation of 6000 Series Servo Tank GaugeGVH480 Diagnostic GVH447 Reference ZeroGVH449 Reference GVH450~459 Temp No.1~10Operating Temperature measurement Primary values VH00 ~ VH09 Operation and Description of Instrument FunctionHart Device designation Device DataElement Temperature 1 VH10 ~ VH15 Element Temperature 2 VH20 ~ VH29Advanced Spot VH28 Lower LimitVH46 Hysteresis Width Item type read and write Default 10mm VH29 Upper LimitVH48 Gas Offset VH49 Liquid OffsetWB Adjustment and Operation Power VH60 ~ VH69 VH53 Element Point Item type select DefaultVH55 Element Volume Item type read and write Range 1 ~ WB primary and Advanced temp VH50 ~ VH59Temperature Adjustment VH70 ~ VH79 VH71 Zero AdjustVH72 Adjust Span VH69 Ref VoltageVH73 Temperature VH74 PositionVH75 Resistance VH76 Resistance AdjVH79 Protect Code Error code VH80 Present ErrorVH81 Temperature Unit VH82 Element Number VH83 No. of PreamblesVH84 Distance Unit VH85 Kind of IntervalDevice setting 2 VH90~VH99 VH88 Short ErrorVH89 Open Error VH90 Device ID Number Item type read and write DefaultVH92 Error Dis. Sel VH94 Polling AddressVH95 Manufacture ID VH96 Software VersionMaintenance Exterior cleaningRepairs Repairs to Ex-approved devicesReplacement GVHTroubleshooting System error messagesSpare parts 1Spare PartsAnchor weight Tall profile AccessoriesAnchor weight Low profile Wire hook, Top anchor 3Wire hook dimensionTechnical data Technical data at a glanceTechnical data Order Structure Process connection SUS304Order Structure Declaration of Contamination Declaration of Contamination FormDeclaration of Contamination Form Index Index 4532 Your official representative Your offical representative