Varec 4532 VH92 Error Dis. Sel, VH94 Polling Address, VH95 Manufacture ID, VH96 Software Version

Page 54

Operation and Description of Instrument Function

Average Temperature/Water Bottom Sensor and Converter

 

 

VH92 Error Dis. Sel.

Item type: select

Default: 0_OFF

Selection: 0_OFF, 1_ON

Type of VH88 "Short Error Value" and VH89 "Open Error Value" display selection.

0_OFF: These 2 error messages will not be transmitted to the connected host gauge. This function automatically excludes defect element in average temperature calculation.

1_ON: Error message will be transmitted to the host gauge. As a result, VH88 and 89"s numeric error code will be displayed on host gauge default screen and may transmit to upper receiver as well.

VH94 Polling Address

Item type: read and write

Default: 2

Range: 1 ~ 15

Polling address for HART communication

VH95 Manufacture ID

Item type: read only

Default: 17

The manufacturer ID for Endress+Hauser instrumentation.

VH96 Software Version:

Item type: read only

A display of installed software version.

VH97 Hardware Version

Item type: read only

A display of installed hardware version.

VH98 Below Bottom

Item type: select

Default: 0_OFF

Selection: 0_OFF, 1_ON

A type of error display when liquid level drops below #1 element (Bottom Point). Error code "29" is displayed on VH80 and VH91 when 0_ON is selected.

VH99 Device Type Code

Item type: read only

Device type will be displayed.

190: Temperature measurement function only.

44

Installation and Operations Manual

Image 54
Contents Installation Page Copyright Disclaimer of Warranties Safety Precaution Definitions Safety Precautions Average Temperature/Water Bottom Sensor and Converter Contents Operation and Description of Instrument Function Index Varec, Inc Contents Introduction Installation and operation overviewIntroduction Software historySystem functional diagram HartSafety instructions Grounding Power supplyWiring ReturnDirect voltage Safety instructions Identification Device designation NameplateScope of delivery CE marks, declaration of conformity Installation Design, dimensionsRecommended procedure Incorrect procedure Flexible tube UnpackingInstallation Instructions Special conditions for safe useInstallation Mounting Mounting instructionMounting on a fixed roof tank Top anchor methodTensioning wire mounting Thermo well method Thermo well applicationAnchor weight method Flexible tube is stabilized by an anchor weightAnchor weight mounting Mounting on a floating roof tank Thermo well method Guide ring and anchor weight method 10Guide ring and anchor weight applicationMounting Wiring Terminal Connection 1 4532 ATC terminal2 6000 Series Servo Tank Gauge terminal 3 4590 TSM i.s. terminal4532 ATC Grounding Wiring Local Hart connection As a Varec tank gauging instrument Device set up 4590 TSMOperating As a standalone generic Hart instrument2 4532 ATC configuration on 6000 Series Servo Tank Gauge 4532 ATC specific parameter set up on the 4590 TSMDevice set up 6000 Series Servo Tank Gauge Preparation of 6000 Series Servo Tank GaugeGVH449 Reference GVH480 DiagnosticGVH447 Reference Zero GVH450~459 Temp No.1~10Operating Hart Device designation Temperature measurement Primary values VH00 ~ VH09Operation and Description of Instrument Function Device DataElement Temperature 1 VH10 ~ VH15 Element Temperature 2 VH20 ~ VH29Advanced Spot VH28 Lower LimitVH46 Hysteresis Width Item type read and write Default 10mm VH29 Upper LimitVH48 Gas Offset VH49 Liquid OffsetVH55 Element Volume Item type read and write Range 1 ~ WB Adjustment and Operation Power VH60 ~ VH69VH53 Element Point Item type select Default WB primary and Advanced temp VH50 ~ VH59VH72 Adjust Span Temperature Adjustment VH70 ~ VH79VH71 Zero Adjust VH69 Ref VoltageVH75 Resistance VH73 TemperatureVH74 Position VH76 Resistance AdjVH79 Protect Code VH80 Present Error Error codeVH81 Temperature Unit VH84 Distance Unit VH82 Element NumberVH83 No. of Preambles VH85 Kind of IntervalVH89 Open Error Device setting 2 VH90~VH99VH88 Short Error VH90 Device ID Number Item type read and write DefaultVH95 Manufacture ID VH92 Error Dis. SelVH94 Polling Address VH96 Software VersionRepairs MaintenanceExterior cleaning Repairs to Ex-approved devicesReplacement GVHTroubleshooting System error messagesSpare parts 1Spare PartsAccessories Anchor weight Tall profileAnchor weight Low profile Wire hook, Top anchor 3Wire hook dimensionTechnical data Technical data at a glanceTechnical data Order Structure Process connection SUS304Order Structure Declaration of Contamination Declaration of Contamination FormDeclaration of Contamination Form Index Index 4532 Your official representative Your offical representative