Varec 4532 manual Spare parts, 1Spare Parts

Page 58

Troubleshooting

Average Temperature/Water Bottom Sensor and Converter

 

 

10.2 Spare parts

Spare parts are contained in kits. Spare parts which you can order from Varec for the 4532 ATC are shown with their order numbers in the diagram below. For more information on service and spare parts, contact Varec.

70106024

017803-0043

70106026

58020200

017802-0008

017803-0044

70106024

Cover, El-housing M88 long type

017803-0043

O-ring, EPDM 88-d3

70106026

Module assembly(Temp. V187)

58020200

Terminal+EMC filter assy.

017802-0008

Cover, (T3) M77

017803-0044

O-ring, EPDM 73-d3

Figure 10-1:Spare Parts

48

Installation and Operations Manual

Image 58
Contents Installation Page Copyright Disclaimer of Warranties Safety Precaution Definitions Safety Precautions Average Temperature/Water Bottom Sensor and Converter Contents Operation and Description of Instrument Function Index Varec, Inc Contents Introduction Installation and operation overviewIntroduction Software historySystem functional diagram HartSafety instructions Grounding Power supplyWiring ReturnDirect voltage Safety instructions Device designation Nameplate IdentificationScope of delivery CE marks, declaration of conformity Installation Design, dimensionsRecommended procedure Incorrect procedure Flexible tube UnpackingInstallation Instructions Special conditions for safe useInstallation Mounting Mounting instructionMounting on a fixed roof tank Top anchor methodTensioning wire mounting Thermo well method Thermo well applicationAnchor weight method Flexible tube is stabilized by an anchor weightAnchor weight mounting Mounting on a floating roof tank Thermo well method Guide ring and anchor weight method 10Guide ring and anchor weight applicationMounting Wiring Terminal Connection 1 4532 ATC terminal2 6000 Series Servo Tank Gauge terminal 3 4590 TSM i.s. terminal4532 ATC Grounding Wiring Local Hart connection As a Varec tank gauging instrument Device set up 4590 TSMOperating As a standalone generic Hart instrument2 4532 ATC configuration on 6000 Series Servo Tank Gauge 4532 ATC specific parameter set up on the 4590 TSMDevice set up 6000 Series Servo Tank Gauge Preparation of 6000 Series Servo Tank GaugeGVH449 Reference GVH480 DiagnosticGVH447 Reference Zero GVH450~459 Temp No.1~10Operating Hart Device designation Temperature measurement Primary values VH00 ~ VH09Operation and Description of Instrument Function Device DataElement Temperature 1 VH10 ~ VH15 Element Temperature 2 VH20 ~ VH29Advanced Spot VH28 Lower LimitVH46 Hysteresis Width Item type read and write Default 10mm VH29 Upper LimitVH48 Gas Offset VH49 Liquid OffsetVH55 Element Volume Item type read and write Range 1 ~ WB Adjustment and Operation Power VH60 ~ VH69VH53 Element Point Item type select Default WB primary and Advanced temp VH50 ~ VH59VH72 Adjust Span Temperature Adjustment VH70 ~ VH79VH71 Zero Adjust VH69 Ref VoltageVH75 Resistance VH73 TemperatureVH74 Position VH76 Resistance AdjVH79 Protect Code Error code VH80 Present ErrorVH81 Temperature Unit VH84 Distance Unit VH82 Element NumberVH83 No. of Preambles VH85 Kind of IntervalVH89 Open Error Device setting 2 VH90~VH99VH88 Short Error VH90 Device ID Number Item type read and write DefaultVH95 Manufacture ID VH92 Error Dis. SelVH94 Polling Address VH96 Software VersionRepairs MaintenanceExterior cleaning Repairs to Ex-approved devicesReplacement GVHTroubleshooting System error messagesSpare parts 1Spare PartsAnchor weight Tall profile AccessoriesAnchor weight Low profile Wire hook, Top anchor 3Wire hook dimensionTechnical data Technical data at a glanceTechnical data Order Structure Process connection SUS304Order Structure Declaration of Contamination Declaration of Contamination FormDeclaration of Contamination Form Index Index 4532 Your official representative Your offical representative