RayTek MI Miniature Infrared Sensor Programming Guide Device Setup, Temperature Calculation

Page 78
Ambient temperature (example)
Control ambient background temp. compensation
Gain adjustment for the temperature signal Offset adjustment for the temperature signal

Programming Guide

11.4 Device Setup

11.4.1 Temperature Calculation

U=C

unit for the temperature value

E=0.950

Emissivity setting (Caution: according to the settings

 

for “ES”, see section 11.4.2 Emissivity Setting and

 

Alarm Setpoints on page 70.)

XG=1.000

Setting for transmission

For the calculation of the temperature value, it is possible to set an offset (relative number to be added to the temperature value), and a gain value.

DG=1.0000

DO=0

In case the ambient temperature is not requested by the internal head temperature, you must set the ambient temperature values as follows:

A=250.0

AC=1

11.4.2 Emissivity Setting and Alarm Set points

The device allows three choices for the emissivity setting and two for the alarm output setting.

ES

Selection of the emissivity setting.

ES=1

Emissivity set by a constant number according to the

 

„E“ command

ES=E

Emissivity set by a voltage on FTC1 (analog input)

ES=D

Emissivity set by the entries in a table (selected by

 

digital inputs FTC1 – FTC 3)

?CE

asks for the emissivity value that is actually used for

 

temperature calculation

70

MI

Image 78
Contents Operating Instructions Declaration of Conformity for the European Community Raytek GmbH Raytek Corporation ContactsEurope United Kingdom FranceWarranty Table of Contents Onnecting to the PC VIA RS232 Output for the Target Temperature Ommand S ET Safety Instructions Safety InstructionsOperating Instructions Description DescriptionTechnical Data Technical DataMeasurement Specifications Emissivity Temperature ResolutionTemperature Coefficient TransmissionTechnical Data Optical Specifications Optical Resolution DSTechnical Data Electrical Specifications Power SupplyOutputs Technical Data Environmental Specifications Technical Data Dimensions Dimensions of Sensing HeadDimensions of Electronic Box Scope of DeliveryMeasurement of Infrared Temperature BasicsBasics Ambient Temperature Basics Emissivity of Target ObjectAtmospheric Quality Basics Electrical Interference Positioning InstallationInstallation Distance to ObjectWiring Sensor Head CableCable for Power Supply and Outputs Cable PreparationConnecting of Cables to the Electronic Box Installation Outputs Signal Outputs and Power SupplySignal Output Wiring of the Signal Output mA orHead Ambient Temp. / Alarm Output Wiring the Output for Head Ambient TemperatureInstallation Wiring the Thermocouple J Compensation Cable Wiring the Thermocouple K Compensation CableThermocouple Output Installation Inputs FTC Overview to the FTC InputsEmissivity Setting analog controlled Ratio between Analog Input Voltage and Emissivity ExampleEmissivity Setting digital controlled Digital Selection of Emissivity with FTC InputsAmbient Background Temperature Compensation Principle of Ambient Background Temperature Compensation Wiring of FTC3 as External Input Trigger and Hold FunctionFTC3 for Holding the Output Temperature Installation Connecting to the PC via RS232 Connecting the RS232 cableInstallation Installing of Multiple Sensors via RS485 Wiring the RS485 InterfaceAddressing through Buttons Addressing through SoftwareInstallation Operation OperationControl Panel Operation Setting the Output Jumper Operation Setting of Modes Mode Range Available ModesOperation Post Processing AveragingOperation Peak Hold Valley Hold Advanced Peak Hold Advanced Valley Hold Advanced Peak Hold with AveragingAdvanced Valley Hold with Averaging Operation Factory Defaults Options OptionsAccessories AccessoriesOverview Standard Mounting Accessories Accessories Adjustable Mounting Bracket Adjustable Mounting Bracket XxxmiacabAccessories Fixed Mounting Bracket Fixed Mounting Bracket XxxmiacfbAccessories Air Purging Jacket Air Purging Jacket XxxmiacajMounting the Air Purge Jacket Accessories Air Cooling System Air Cooling SystemAir Flow Accessories Air Cooling System T‐Adapter Dimensions of Air Cooling System Accessories Right Angle Mirror Right Angle Mirror * with Air PurgingAccessories Box Lid Box Lid with View Port for Post InstallationsAccessories Protective Window Protective Window XxxmiacpwTroubleshooting Minor Problems MaintenanceMaintenance TroubleshootingMaintenance Fail‐Safe Operation Error Codes for the OutputsError Codes via RS232/485 Error Codes via RS232/485 Error Codes for the LCD DisplayError Codes LCD Display Maintenance Sensing Head Exchange Maintenance Software SoftwareProgramming Guide Programming GuideSettings Return from the burst mode to the poll modeProgramming Guide Transfer Modes Setting a parameter Poll Mode Programming Guide General Command StructureRequesting a parameter Poll Mode Device response formatError message Device InformationDevice Information Emissivity Setting and Alarm Set points Programming Guide Device SetupTemperature Calculation Selection of the emissivity settingTable for Emissivity and Set Points Dynamic Data Post ProcessingFactory default values Output for the Target TemperatureAlarm Output Programming Guide Device ControlLock Mode Mode Setting for the Digital Input FTC3Changing the Sensing Head Calibration Data Setting the command ES = D Programming Guide Multiple Units RS485 Multidrop Mode Changing an addressProgramming Guide Command Set LCDDescription LT ‐40 to 600C ‐40 to 1112F = number, X = uppercase letter Command Set Appendix AppendixDetermination of Emissivity Appendix Appendix Typical Emissivity Values Metals Tab Typical Emissivity Values for Metals NON -METALS Tab Typical Emissivity Values for Non‐MetalsIndex Index