Single−Piece Installation
The following steps should be followed for the installation of the single−piece configuration.
1.Remove cover from Equipment Control Module by pressing the two tabs on the bottom edge and pulling away. Route wires through large hole in Equipment Control Module. Level Equipment Control Module against wall (for aesthetic value only − Equipment Control Module need not be leveled for proper operation) and mark wall through 4 mounting holes.
2.Drill two 3/16−in. mounting holes in wall where marked. Thermidistat Control may be mounted to a standard junction box if desired. Hole pattern on Equipment Control Module matches junction box mounting holes.
3.Secure rear plastic Equipment Control Module to wall with 4 screws and anchors provided. To avoid unintended bending of wall plate plastic, use all 4 screws and anchors. Make sure all wires extend through hole in Equipment Control Module.
4.Adjust length and routing of each wire to reach proper connector block and terminal on Equipment Control Module with 1/4−in. (6 mm) extra length. See Fig. 14.