Harmar Mobility CPL1000, CPL600, CPL1400, CPL400, CPL1200 manual Installing Auto-folding Ramp optional

Page 8

8

Installing Auto-folding Ramp (optional)

Step 1

Install the ramp roller guide on the side of the lift tower using the screws already installed in the panels.

Step 2

Attach the two ramp pivot tabs to the lower landing sides of the platform. Reinsert the hex bolts, one of which will go through the guard panel post, and tighten.

Step 3

Attach the ramp to the pivot tabs using shoulder bolts and locking nuts. Tighten the nuts until they seat against the bolt shoulder.

Step 4

Attach the ramp roller arm by bolting it to the underside of the ramp.

The ramp roller should align and make contact with the ramp roller guide.

Image 8
Contents G H L a N D E R Table of Contents Using the ManualSafety When You Receive the LiftSpecifications Code Requirements Site RequirementsRequired tools Required materialsPreparing to Install the Lift Controller Harness ConnectionsInstalling the Platform StepInstalling the Outer Guard Panels Installing Fixed RampInstalling Auto-folding Ramp optional Anchoring the Lift Setting the Limit Switches Verifying Operation of the Lift Manual Override Call-Sends optionalTop Landing Gate optional EMI Interlock EMI and Flush Strike Interlocks optionalFlush Strike Interlock Platform Gate optional Fascia Panel optional Commercial Platform Lift Owners Section Read the manual thoroughly before operating the liftSafety Controls Emergency StopDown Keylock optionalOperating the Lift Down Please rate your satisfaction with your Harmar dealer How did you hear about Harmar?Purchased my Harmar lift because