14
EMI and Flush Strike Interlocks (optional)
The optional EMI or Flush Strike Interlocks are provided with a combination mechanical lock and electric contact. They are to be used with existing doors.
The interlock:
•Prevents the lift from running if the door is not closed.
•Prevents the door from being opened if the platform is not at the landing.
•Unlocks when the lift is on the landing limit switch.
Flush Strike Interlock
Refer to the instructions inside the strike box for mounting requirements.
EMI Interlock
1)Position interlock to door jamb and mark mounting holes.
2)Fasten Interlock to door jamb with #8 wood screws.
3)Route
4)Attach door keeper and emergency key plates to hoistway door.
.
A length of multi‐conductor wire will need to be ran from the bottom of the lift tower to the interlocks. Consult local codes for type and mounting requirements. After wiring is completed, the wiring harness must be plugged into it appropriate receptacle on the controller (ref pg 5).
Wiring Connections
Flush Strike | Lift Harness |
Yellow / *Black | Black |
Yellow / *Purple | Green |
White | White |
Orange | Orange |
Blue | Blue |
Brown | Brown |
*Colors when used on a DC (battery) powered lift option.
EMI | Lift Harness |
Black (A) | Black |
Black (B) | Green |
Yellow (C) | White |
Yellow (D) | Orange |
N/A | *Blue |
N/A | *Brown |
*Must be tied together when using an EMI Interlock.