Genie TZ-50 manual Electrocution Hazards, Tip-over Hazards

Page 4

Operator's Manual

Second Edition • First Printing

 

 

 

 

SAFETY RULES

Electrocution Hazards

This machine is not electrically insulated and will not provide protection from contact with or proximity to electrical current.

Maintain safe distances from electrical power lines and apparatus in accordance with applicable governmental regulations and the following chart.

Voltage

 

Minimum Safe

Phase to Phase

Approach Distance

 

Feet

Meters

 

 

0 to 300V

Avoid Contact

 

 

 

300V to 50KV

10

3.05

 

 

 

50KV to 200KV

15

4.60

 

 

 

200KV to 350KV

20

6.10

 

 

 

350KV to 500KV

25

7.62

 

 

 

500KV to 750KV

35

10.67

 

 

 

750KV to 1000KV

45

13.72

 

 

 

Allow for platform movement, electrical line sway or sag and beware of strong or gusty winds.

Keep away from the machine if it contacts energized power lines. Personnel on the ground or in the platform must not touch or operate the machine until energized power lines are shut off.

Do not operate the machine during lightning or storms.

Do not use the machine as a ground for welding.

Tip-over Hazards

Occupants, equipment and materials shall not exceed the maximum platform capacity.

Maximum capacity

ANSI and CSA models

500 lbs

227 kg

CE and Australia models

440 lbs

200 kg

 

 

 

Maximum occupants

 

2

 

 

 

Do not raise the boom unless the machine is level.

Do not set the machine up on a surface where it cannot be leveled using only the outriggers.

Do not raise the boom unless all four outriggers are lowered, the footpads are in firm contact with the ground and the machine is level.

Do not set the machine up unless it is on a firm surface. Avoid drop-offs, holes, unstable or slippery surfaces and other possible hazardous conditions.

Do not move the machine when the boom is raised.

Do not adjust or stow the outriggers when the boom is raised.

2

Genie TZ-50

Part No. 114164

Image 4
Contents Operator’s Manual Contents Contact usSafety Rules Do Not Operate UnlessElectrocution Hazards Tip-over HazardsMaximum allowable manual force CE and Australia 400 N Fall Hazards Collision HazardsExplosion and Fire Hazards Component Damage HazardsBodily Injury Hazard Damaged Machine HazardsTowing Hazards Optional Drive System Safety Tip-over Hazards Decal LegendBattery Safety Burn Hazards Explosion HazardsTip-over Hazard Lifting HazardControls Ground Control PanelStop Platform Control PanelStop Drive Control Panel OptionPre-operation Inspection FundamentalsPre-operation Inspection Maintenance Maintenance Symbols LegendObserve and Obey Check the BatteriesCheck the Tires and Wheels Check the Hydraulic Oil LevelScheduled Maintenance Check the Engine Oil Level if equippedSetup for Function Tests Function TestsTest Boom Functions and Function Enable Test the Parking BrakeAt the Ground Controls Test Emergency StopTest Outrigger Interlock At the Platform ControlsTest the Tilt Sensor Test Drive and Brake System if equipped Workplace Inspection Workplace InspectionEmergency Stop Operating InstructionsOnly use the machine as it was intended Setup for Operation Operation from GroundOperation from Platform Starting the Engine if equippedManual Operation of Functions All models except AustraliaAustralian models only Manual Operation of Jib Australian models onlyFall Protection Platform Overload Indicator Light if equippedOptional Drive System Operation Driving on a slope To determine the slope gradeAfter Each Use StorageMoving Machine Without a Tow Vehicle TowingTowing Information Charging the Batteries with the Engine Battery Charging Instructions Observe and ObeyCharging the Batteries with the AC Charger Transport and Lifting Instructions Securing to Truck or Trailer for Transit Securing the ChassisCenter of Gravity Table Lifting InstructionsAxis Chassis Lifting Points Decals Inspection for Decals with WordsGround Controls Side Platform EndInspection for Decals with Symbols Ground Controls Side Specifications Power sourceRange of Motion Chart Reporting Safety Defects Reporting Safety DefectsGenie Industries PO Box Redmond, WA Before Towing Before Driving