Invacare Excelerator XLT manual SAFETY/HANDLING Excelerator, Procedure, Stability and Balance

Page 6

G

E N E R A L

G U I D E

PROCEDURE 1

GENERAL GUIDELINES

WARNING

TIRE PRESSURE

DO NOT use your Excelerator unless it has the proper tire pressure (p.s.i.). DO NOT overinflate the tires. Failure to follow these suggestions may cause the tire to explode and cause bodily harm.

DO NOT ride on a flat or underinflated tires. Riding on flat or underinflated tires can cause injury, as well as, damage to the tire, tube and bicycle.

WEIGHT LIMITATION

The Invacare Excelerator and Excelerator XLT/XLT 2000 have a maximum weight limitation of 250 lbs.

The Invacare Li'l Excelerator has a maximum weight limitation of 150 lbs.

L

I

N E S

SAFETY/HANDLING OF

EXCELERATOR

“Safety and Handling” of the Excelerator requires the close attention of the user as well as the assistant. This manual points out the most common procedures and techniques involved in the safe operation and mainte- nance of the Excelerator. It is important to practice and master these safe techniques until you are comfortable in maneuvering the Excelerator.

Use this information only as a “basic” guide. The tech- niques that are discussed on the following pages have been used successfully by many.

Individual users often develop skills to deal with daily living activities that may differ from those described in this manual. Invacare recognizes and encourages each individual to try what works best for him/her in overcom- ing obstacles that they may encounter. Techniques in this manual are a starting point for the new Excelerator user and assistant with “safety” as the most important consideration for all.

Stability and Balance

For stability and proper operation of your Excelerator, you must at all times maintain proper balance. Your Excelerator should remain upright and stable during normal daily ac- tivities when operated correctly.

Invacare recommends using seat positioning straps for additional safety.

A Note to Excelerator Assistants

When learning assistance techniques for the Excelerator, have an experienced assistant help you before attempt- ing it alone.

When you are assisting with a transfer to / from the Excelerator, remember to use good body mechanics. Keep your back straight and bend your knees whenever lifting or positioning the Excelerator for the end-user.

Also, be aware of detachable parts. These must NEVER be used for lifting supports, as they may be inadvertently released, resulting in possible injury to the user and/or assistant.

Percentage of Weight Distribution

Transferring in and out of the Excelerator will cause a change to the normal balance, the center of gravity, and the weight distribution of the Excelerator. To determine and establish your particular safety limits, practice trans- ferring activities in several combinations in the presence of a qualified health care professional BEFORE attempt- ing a transfer alone.

Proper positioning is essential for your safety.

Transferring into/out of the Excelerator (FIGURE 1)

WARNING

Before attempting to transfer IN or OUT of the Excelerator, every precaution should be taken to reduce the gap distance. Position the Excel- erator on level ground and as close as possible to the object you are transferring INTO or OUT of. The parking brake of the Excelerator MUST be en- gaged and the object you are transferring INTO or OUT of MUST also be secured before attempt- ing any transfer.

CAUTION

When transferring, position yourself as far back as possible in the seat. This will prevent damage to the upholstery.

6

Image 6
Contents Excelerator Lil Excelerator Excelerator XLT Special Notes E C I a L T E STable of Contents Specification S SpecificationsGeneral Guidelines Operating InformationPercentage of Weight Distribution SAFETY/HANDLING ExceleratorProcedure Stability and BalanceHand Crank Footrest Seat Frame Safety Inspection Checklist ProcedureMaintenance Safety Precautions MaintenanceSafety INSPECTION/TROUBLESHOOTING/MAINTENANCE Suggested Maintenance ProceduresEXCELERATOR/LIL Excelerator Assembly Procedures Figure Excelerator XLT/XLT 2000 Assembly Procedures Figure Assembly ProceduresINSTALLING/ADJUSTING the Rear Wheel QUICK-RELEASE Axles A RRear Wheels Adjusting Toe In/Toe OutReplacing Camber Inserts Figure A R E E L SExcelerator XLT/XLT Excelerator XLT/XLT 2000 FORK/CRANK Assembly Replacement FORK/SPRING/CRANKTension Spring Replacement/Adjustment Figure Removing Tension SpringAdjusting Tension Spring Road Crown Compensator Replacement/ Adjustment FigureProcedure B Figure LIL Excelerator Three 3 Speed Shifter Cable AdjustmentProcedure a Figure E E D I F T E R SSpeed Shifters Slot Clickbox OpeningEXCELERATOR/LIL Excelerator Chain Adjustment A I NExcelerator XLT Chain Adjustment ChainAdjustment Using Parking Brake FigureParking Brake ADJUSTMENT/ Replacement Figure ReplacementBACK/SEAT C K A TExcelerator/Lil Excelerator Figure Excelerator XLT/XLT 2000 Back Angle Adjustment Figure Excelerator XLT/XLT 2000 FigureUpholstery Seat Upholstery Replacement FigureBack Upholstery Replacement H O L S T E R YAdjusting Footrest Depth Adjusting Footrest HeightAdjusting Footrest Angle O T R E S TFootrest FootrestLeg Guard Excelerator XLT/XLT USING/REPLACING Footrest Strap Using Footrest Strap FigureReplacing Footrest Strap Figure Operation Hand Crank AssemblyShifting Gears E R a T I O NBraking Procedure OperationBACKING-UP Parking BrakeOperation Procedure STEERING/CORNERINGBearing Play Adjustment Figure Adjusting Gear Shift Push Button FigureComputer Installation Figure Water Bottle Installation FigureRear Safety Light Figure Seat Positioning Strap Installation FigureSafety Helmet Figure Procedure OptionsLateral Support Figure Warranty R R a N T YOne InvacareWay