Key Service Unit (KSU)
The KSU is a plastic cabinet designed for wall mounting. The KSU contains a MBU(Main Board Unit) and POWER Transformer and Mechanical parts.
Main Board Unit (MBU)
A Power Supply Circuit is required in the Key Service Unit. The Power Supply Circuit converts local AC power(220~240V AC @ 50~60Hz) to DC voltages, regulates the voltages, and provides the appropriate DC voltages to the MBU for distribution to other system components. Three DC outputs are provided : ±5V DC, +30V DC.
The MBU, incorporates, master clock, one alarm detection circuit, one general purpose relay, watchdog circuitry and 4 ports digital terminal interface circuits and 2 ports SLT circuits as well as the system's PCM voice processing and main
The
There are two commonly used slots, SLOT2 and SLOT3, and four fixed slots for extending the system capacity. From the left side, the SLOT1 is used to install the DVIB/DVIBE. The SLOT2 and SLOT3 are used to install LCOB2/LCOB/LCOBE/LCOBA/LCOB4 and STIB2 / STIB. The SLOT4 is used to install the PMU basically. The SLOT5 is used to install the WTIB and the SLOT6 is used to install the MFB.
The permitted terminals are as following.
Keyset:
DECT terminal:
Program Module Unit (PMU)
The PMU is installed to SLOT4 basically and incorporates the system's memory, one internal and one external MOH ports, Real time clock circuit and two DTMF receivers. Each receiver is
The LEDs in upper side of the PMU panel indicates system’s power on/off state and data communication state. Also, the PMU contains 512Kbytes of RAM and 1Mwords of Flash memory.
The RAM associated with the system database and the
Two(2) Flash memory(U1 & U2, 512Kwords respectively) contains the basic system operating software.
Ring Generation Unit(RGU)
The
The RGU is installed to connector,CN23,of MBU and generates 75Vrms ring signal that can be applied to the two(2) SLTs simultaneously.
Multi Function Board (MFB)
The Multi Function Board(MFB) Provides a
The MFB includes circuitry for float charging an externally connected 24 volt battery and controls the operation of the battery