LG Electronics GDK-20W, LKD-8DS LCD Message of Unsubscribed GDC-335H GAP and GDC-340HGAP

Page 57

GDK-20W DIGITAL WIRELESS KEY TELEPHONE SYSTEM

Base Station Cabling

The Base Station is connected to the WTI(wireless terminal interface) ports of GDK-20W KSU by a twisted one pair copper line. The following rules should be obeyed:

The cable for connecting the KSU with a base station should be a twisted pair cable.

The cable for connecting the KSU with a base station shall be separately cabled. This connection shall be cabled separate to the building cabling using one pair CAT5 cabling.

Twisted pair shielded cables should be used with all outdoor configurations. The following characteristics should be observed for all cables:

DC resistance: The resistance of a conductor should not exceed 73.4 ohm per km for a temperature of 20 degree.

Attenuation: The attenuation of any pair should not exceed 17 dB per km on condition of a temperature of 20 degree and frequency of 1 MHz.

Characteristic impedance: Characteristic impedance should remain in the range of 100 ohm _ 15% for a frequency of 1 MHz.

Crosstalk: The total crosstalk of any pair (Far-end and Near-end crosstalk), measured over a line length of 1800 metres should not exceed 40 mV.

The maximum connection length depends upon cable size(φ). [Table 3.6.4] shows the resistance and the maximum cable length.

Cable Type

Resistance

Maximum Cable Length

0.4 mm cable (Awg26)

0.27 /m

150m

0.5 mm cable (Awg24)

0.18 /m

300m

0.6 mm cable (Awg22)

0.11 /m

450m

[Table 3.6.4] Cable Resistance and Maximum Cable Length

Wireless Terminal Installation

To install GDC-335H (GAP) and GDC-340H (GAP), simply take out the handset and batteries (330-SBP, rechargeable battery), charger (330-SSC, 340-SSC) and AC/DC adapter (330-HAP) from the package and assemble it. Before using the GDC-335H and GDC-340H, you should recharge the battery fully.

After inserting a battery, press the power button of GDC-335H (GAP) and GDC-340H (GAP). Figure 3.6.20 shows the initial LCD. The two icons in the left upside of the LCD are blinking until the GDC-335H is subscribed. (In GDC-340H, these icons are not displayed until the GDC-340H is subscribed)

T RYSUBS.

Figure 3.6.20 LCD Message of Unsubscribed GDC-335H (GAP) and GDC-340H(GAP)

Before using the GDC-335H(GAP) and GDC-340H(GAP), it should be subscribed. Figure 3.6.21 shows the LCD message of the subscribed GDC-335H(GAP) and GDC-340H(GAP).

STAXXX

Figure 3.6.21 LCD Message of Subscribed GDC-335H (GAP) and GDC-340H (GAP)

Refer to the User Guide of the GDC -335H and GDC-340H for the detail information.

59

Image 57
Contents Digital Wireless Key Telephone System Installation Manual Revision History Table of Contents Admin Programming Regulatory Information PurposeHearing AID Compatibility Replacement of Lithium BatteriesPictures Interference and AttenuationAbbreviations Introduction Isdn BRI System CapacityPMU MFBSTA Isdn1 Dimensions & Weights Height Width Depth System SpecificationsFlash Memory 4 Electrical Specifications AWG WireLcobesp System ComponentsMain Board Unit MBU Key Service Unit KSUProgram Module Unit PMU Ring Generation UnitRGUWireless Terminal Interface Board Wtib Interface Board STIB2Interface Board Stib Dvib Digitized Voice Interface Board General Site Considerations Site PreparationVerify On-Site Equipment Back-Board InstallationMounting the KSU KSU & Power Installation2 KSU Mounting Holes & Installation layout Power InstallationKSU Grounding PCB Installation PCB Handling & General InstallationMain Board Unit MBU Installation 2 MBU Installation OFF PMU Installation MFB Installation RGU InstallationSW1 Isdn STIB2 & Stib S/T Interface Board InstallationCN2 SW2 SW1 CN2SW2 SW2Dvib Digitized Voice Interface Board Installation Wtib Wireless Terminal Interface Board Installation11 Connectors of the Dvib Battery Back-Up Wiring Installation System WiringGeneral Purpose Relays Wiring Music on Hold MOH WiringFerrite Core Installation Alarm Detect Port Wiring4 Ferrite core on signal wires Components of the Dect system Overview of the Dect system1 Components of a Dect system GDK-20W Digital Wireless Key Telephone System Wtib Wireless Terminal Interface BoardBase Station GDC-200B Before Making Initial Call How to make CallsControlling a Call Terminating a CallBase Station GDK-20W DectAntenna Diversity Subscription Low Battery Alarm 8 Single-Slot Charger 330-SSC, 340-SSC System Configuration Before InstallationSite Survey Base Station Broadcast Range and Location 9 Base Station Service AreaGeneral Guidelines CRSCell-Coverage Region Survey ToolDistance Fading Reporting Results Rssi Monitoring Possible in GDC-335H onlyCheck list for Survey Data Korea Dect Survey Report Template NumberExamples Example 1 Centralizing Base StationsExample 2 Base Station Coverage in Adjoining Areas 15 Location of Base Station in Office Environment Example 3 Maximizing Line of SiteEquipment Check Hardware InstallationWtib Installation Unit Installation18 Wall Mounting of Base Station without wedge 20 LCD Message of Unsubscribed GDC-335H GAP and GDC-340HGAP System ID User subscription/desubscriptionConditions Authentication CodeAt the GDC-335H User SubscriptionAC code + User Desubscription At the GDC-340H Menuup or Down Summary of Dect Installation Stib Isdn DescriptionBasic Features of Isdn Device S-Interface GDK-20W Digital Wireless KEY Telephone System Features of Isdn CO Line T-Interface Unknown / National Type / International / Subscriber System Capacities GDK-20WRemark Numbering PLAN*1 Feature CodesMON+DND/FOR+7 TRANS/PGM+#4MON+DND/FOR+# TRANS/PGM+*1Basic and Extended Numbering Plans Features Basic Extension RemarksLCD Months SLT, DND SLT/WHTU*2Tone / Ring Cadence Audible SignalsSLT SLT Ring CadenceFrequencies and Tones GDK-20W Digital Wireless KEY Telephone System GDK-20W Station Configuration with LKD 2B GDK-20W ConfigurationMaximum Number of Stations in GDK-20W 34 Ports Maximum Number of CO Lines in GDK-20W 8 PortsNumber of Ports Default Number Description Wireless Cell / Terminal ConfigurationMaximum Number of Ports Station / CO in GDK-20W 38 Ports Gain Controlsystem Basemain Menu 5 SUB MenuSLT Rx Gain Country CIS Dktu SLT DCOSLT DCO Admin Program Start Press Flex KEY1-12 To Enter the Programming ModeGeneral Description IntroductionMAIN-MENU HOW to ProgramSUB-MENU TERMINAL-MENUProcedure Example of Admin. ProgramDND YESStation Attribute Button DefinitionAdmin Programming Admin Programming IndexFlex KEY Main Menu SUB Menu SYS TMR SYS PGMUCD SUB Menu Flex KEY Terminal Menu Range Default Remark Default ValuesLoop PBX / CO SUB Menu Flex Terminal Menu Range Default Remark KEYIsdn CO Colp Didrn2.3 Isdn Program Main Menu Flex SUB Menu Terminal Range Default Remark KEYSYS / EXC DID/DISASmdr Dtmf RX DktuTone MUSIC1YES/NO DVU SUB Flex SUB Menu Range Default Remark KEY TimerFlex KEY SUB Menu Terminal Menu Default Remark Disable Override Always Flex KEY SUB Menu Range Default RemarkLDT DMT2.10 Hunt GROUP/VOICE Mail Program Main Menu