D. RSSI Monitoring (Possible in GDC-335H only)
This function helps that the dealer can install base stations without CR instrument. The RSSI (Received Signal Strength Indicator) level of a base station of which the wireless terminal is locked is displayed as dBm value on the LCD (The limit is
zPress FUNCTION() button.
zPress * .
zTo enter Technician menu, press PIN code (‘L’,’G’,’G’,’A’,’P’ = ‘5’,’4’,’4’,’2’,’7’).
zPress FUNCTION() button.
zTechnician Main Menu is displayed on the LCD.
z | Press | 4 | (Or set ‘<’ mark to ‘4 ShowRSS’ to press UP( ) button or DOWN( ) button and press |
|
FUNCTION() button.).
(The RSSI value is displayed on the LCD and the value is updated periodically.)
zPress FLASH button to return to Main Menu.
E. Reporting Results
It is important to make a comprehensive survey report that records test results and provides useful information for the engineer who actually install the equipment. The following information should be included in the survey report (see Survey Template):
zA description of the site, explaining which buildings and grounds are to be included in the report. A description of the topography of outdoor areas may be useful.
zA specification of the construction of the buildings and construction materials.
zDetermine the customer requirements for; 9 the number of wireless terminals 9 required coverage
9 performance requirements (traffic density, grade of service, etc.)
zThe location of the
zCabling details. Include a specification of cables already present on the site and a list of new cabling required. Include the distance between a base station and a WTIB for existing and new cabling.
zCopies of the maps of the site with the positions of base stations and the cell boundaries. Different cell boundaries can be marked with different patterns to avoid confusion, i.e. dotted, dashed, dot dash, etc. Do not use colors as these may be lost when photocopying.
Use the following numbering conventions:
xwyy refers to the identity of the base station, where;
x is the level
yy is the base station position number. This number should be unique.
xcyy refers to the identity of the cell, where;
x is the level at which the measurement was made.
yy is the base station position number that is being measured.
51