WTIB (Wireless Terminal Interface Board) Installation
The WTIB provides 2 ports of base station interfaces. The connection between the WTIB and base
The exterior of the board is shown in Figure 3.4.10.
It should be noted that the WTIB board could be installed on the SLOT5.
Figure 3.4.10 WTIB
DVIB (Digitized Voice Interface Board) Installation
The DVIB provides 2 voice channels. The maximum record time of a DVIB without DVEU(Digitized Voice Expansion Unit) is 68 minutes and if a DVEU is installed, additional 70 minutes is added to the maximum record time. And the protection of recorded messages is controlled by MBU
MBU | Description | System message | User message | |
|
|
|
| |
OFF : for system default | Not deleted | Deleted | ||
|
|
| ||
ON : for database protection | Not deleted | Not deleted | ||
| ||||
|
|
|
|
[Table 3.4.4] Protection of recorded messages
The DVIB board should be installed on the SLOT1 of MBU. And the DVEU board should be installed correctly on the CN4 and CN5 of DVIB. If the boards are incorrectly installed, DVIB or DVEU may be operated abnormally or damaged.
The connectors of a DVIB board is shown in figure 3.4.11. CN2 is used for the trace of a DVIB board using a trace data monitor
31