Agilent Technologies Option 100, E2625A manual Standard Masks

Page 26

Standard Masks

The Infiniium Option 100 and the E2625A Telecommunications Mask Template Kit disk contains standard masks used by the telecommunications and data communications industries. These are the masks you can load into the oscilloscope to test your waveform’s compliance against industry standards.

To use any of these masks, follow the procedures in chapter 2.

Standard Masks

The types of standard masks include:

ITU G.703 International Standard Masks

ANSI T1.102 North American Standard Masks

FCC Part 68.308 Options A, B, and C Masks

Pre-Compliance SONET Masks

IEEE 802.3 Masks

ITU G.703 International Standard Masks

Mask File Name

Line Impedance

Bit Rate

1544kb_ITU_DS1.msk

100 twisted pair

1.544 Mbps

2Mb_ITU_120.msk

120 twisted pair

2.048 Mbps

2Mb_ITU_75.msk

75 coax

2.048 Mbps

6312kb_ITU_110_DS2.msk

110 twisted pair

6.312 Mbps

6312kb_ITU_75_DS2.msk

75 coax

6.312 Mbps

8Mb_ITU.msk

75 coax

8.448 Mbps

34Mb_ITU.msk

75 coax

34.368 Mbps

44736kb_ITU_DS3.msk

75 coax

44.736 Mbps

140Mb_ITU_0.msk

75 coax

139.264 Mbps

140Mb_ITU_1.msk

75 coax

139.264 Mbps

140Mb_ITU_1_INV.msk

75 coax

139.264 Mbps

155Mb_ITU_0.msk

75 coax

155.520 Mbps

155Mb_ITU_1.msk

75 coax

155.520 Mbps

155Mb_ITU_1_INV.msk

75 coax

155.520 Mbps

3-2

Image 26
Contents User’s Guide Getting Started and Using Masks This BookContents Contents-2 Page Adding Option 100 to an existing Infiniium Oscilloscope What not to do Recommended accessoriesSupplied items Oscilloscope models Channels Bandwidth Sample RateTo access the Mask Test Setup dialog box Overview of the Mask Test Setup dialog box Is enabledGetting Started and Using Masks Getting Started and Using Masks Introduction to Mask TestingHow Infiniium does Mask Testing Make a copy of the Mask Test diskTo install the Standard Masks Load Mask dialog box will resembleTo calibrate the oscilloscope Cal Memory ProtectTo choose a proper probe for Mask Testing Calibrating the probe adapterTo get your waveform on the oscilloscope display To enable the Mask Test To load a Mask Locate the Use File Setup When Aligning option To align a Mask to the waveformStarts mask test in the Mask Test Setup dialog box To start and stop the Mask TestTo understand the Mask Test tab description area To run the Mask Test conditionally To stop the Mask Test on the first failure Analyzing a failureStandard Masks Standard Masks Pre-Compliance Sonet Masks ITU G.703 International Standard Masks 2MbITU75.msk 6312kbITU110DS2.msk 6312kbITU75DS2.msk 8MbITU.msk 34MbITU.msk 44736kbITUDS3.msk 140MbITU0.msk 140MbITU1.msk 140MbITU1INV.msk 155MbITU0.msk 155MbITU1.msk 155MbITU1INV.msk Ansi T1.102 North American Standard Masks DS1CANSI.msk DS2ANSI.msk DS3ANSI.msk DS4NAANSI.msk DS4NAANSIMAX.msk STS1ANSIEYE.msk STS1ANSIPULSE.msk STS3ANSI.msk STS3ANSIMAX.msk FCC Part 68.308 Options A, B, and C Masks FCC68OPTC.msk Pre-Compliance Sonet Masks OC12SONET.msk Ieee 802.3 Masks 100BASETXSTP 100BASETXUTP Safety Document Warranty