To understand the Mask Test tab description area

To understand the Mask Test tab description area

After you have enabled the mask test in the Mask Test Setup dialog box, you will see a Mask Test tab on the lower left of the oscilloscope screen, beneath the waveform viewing area. The description area below the Mask Test tab shows:

Mask title

Amplitude specifics (for ANSI T1.102 North American Standard Masks only)

Total number of waveforms in the duration of the mask test

Number of failed waveforms in the mask test

Regions in the mask

Waveform violations

Mask Test tab

Description area

When any of the ANSI T1.102 North American Standard Masks are loaded, the Mask Test tab description area will show minimum and maximum amplitude values. These values are the result of testing for specifics of the standard, and indicate the upper or lower limit that the standard allows.

2-12

Image 22
Contents User’s Guide Getting Started and Using Masks This BookContents Contents-2 Page Adding Option 100 to an existing Infiniium Oscilloscope Supplied items Recommended accessoriesWhat not to do Oscilloscope models Channels Bandwidth Sample RateTo access the Mask Test Setup dialog box Overview of the Mask Test Setup dialog box Is enabledGetting Started and Using Masks Getting Started and Using Masks Introduction to Mask TestingHow Infiniium does Mask Testing Make a copy of the Mask Test diskTo install the Standard Masks Load Mask dialog box will resembleTo calibrate the oscilloscope Cal Memory ProtectTo choose a proper probe for Mask Testing Calibrating the probe adapterTo get your waveform on the oscilloscope display To enable the Mask Test To load a Mask Locate the Use File Setup When Aligning option To align a Mask to the waveformStarts mask test in the Mask Test Setup dialog box To start and stop the Mask TestTo understand the Mask Test tab description area To run the Mask Test conditionally To stop the Mask Test on the first failure Analyzing a failureStandard Masks Standard Masks Pre-Compliance Sonet Masks ITU G.703 International Standard Masks 2MbITU75.msk 6312kbITU110DS2.msk 6312kbITU75DS2.msk 8MbITU.msk 34MbITU.msk 44736kbITUDS3.msk 140MbITU0.msk 140MbITU1.msk 140MbITU1INV.msk 155MbITU0.msk 155MbITU1.msk 155MbITU1INV.msk Ansi T1.102 North American Standard Masks DS1CANSI.msk DS2ANSI.msk DS3ANSI.msk DS4NAANSI.msk DS4NAANSIMAX.msk STS1ANSIEYE.msk STS1ANSIPULSE.msk STS3ANSI.msk STS3ANSIMAX.msk FCC Part 68.308 Options A, B, and C Masks FCC68OPTC.msk Pre-Compliance Sonet Masks OC12SONET.msk Ieee 802.3 Masks 100BASETXSTP 100BASETXUTP Safety Document Warranty