Introduction to Option 100 and E2625A Telecommunications Mask Template Kit

Supplied items

Supplied items

The Option 100 Telecommunications Mask Template Kit contains the following items:

Mask Template

Description

Separately Orderable

Kit Item

 

Agilent Part Number

Floppy disk

Mask template library floppy disk

E2626A

Adapter

100/110/120 differential impedance adapter

E2621A

 

with bantam (f) connector, bantam (m) to

 

 

Siemens (f) adapter cable

 

Adapter cable

Bantam (m) to Siemens (f) adapter cable

E2623A

Adapter

75 single-ended impedance adapter with

E2622A

 

BNC (f) connector

 

Adapter cable

Dual-bantam (f) to RJ48C (m) adapter cable

E2624A

Adapter/coupler

RJ48C (f) to RJ48C (f)

E2627A

Adapter

Bantam (m) to BNC (f); for system verification of

E2628A

 

E2621A adapter and Infiniium oscilloscope

 

Adapter

BNC (m) to BNC (f) 50-to-75 ohm adapter; for

E2629A

 

system verification of E2622A adapter and Infiniium

 

 

oscilloscope

 

Cable

BNC (m) to BNC (m) cable; 30 cm long

8120-1838

Storage case

Hard-shell case for storage of all kit accessories

E2625-45501

Recommended accessories

Other Agilent accessories recommended for use in mask testing include:

Agilent Part

Accessory Item

Description

Number

 

 

E2630A

Patch cable

Bantam (m) to bantam (m) patch cable

E2632A

Patch cable

Siemens (m) to Siemens (m) patch cable

What not to do

You should not use the Mask Test master disk for daily use. Instead, you should use a copy of the master disk, as described in Chapter 2.

1-3

Image 7
Contents User’s Guide This Book Getting Started and Using MasksContents Contents-2 Page Adding Option 100 to an existing Infiniium Oscilloscope Supplied items Recommended accessoriesWhat not to do Channels Bandwidth Sample Rate Oscilloscope modelsTo access the Mask Test Setup dialog box Is enabled Overview of the Mask Test Setup dialog boxGetting Started and Using Masks Introduction to Mask Testing Getting Started and Using MasksMake a copy of the Mask Test disk How Infiniium does Mask TestingLoad Mask dialog box will resemble To install the Standard MasksCal Memory Protect To calibrate the oscilloscopeCalibrating the probe adapter To choose a proper probe for Mask TestingTo get your waveform on the oscilloscope display To enable the Mask Test To load a Mask To align a Mask to the waveform Locate the Use File Setup When Aligning optionTo start and stop the Mask Test Starts mask test in the Mask Test Setup dialog boxTo understand the Mask Test tab description area To run the Mask Test conditionally Analyzing a failure To stop the Mask Test on the first failureStandard Masks Standard Masks Pre-Compliance Sonet Masks ITU G.703 International Standard Masks 2MbITU75.msk 6312kbITU110DS2.msk 6312kbITU75DS2.msk 8MbITU.msk 34MbITU.msk 44736kbITUDS3.msk 140MbITU0.msk 140MbITU1.msk 140MbITU1INV.msk 155MbITU0.msk 155MbITU1.msk 155MbITU1INV.msk Ansi T1.102 North American Standard Masks DS1CANSI.msk DS2ANSI.msk DS3ANSI.msk DS4NAANSI.msk DS4NAANSIMAX.msk STS1ANSIEYE.msk STS1ANSIPULSE.msk STS3ANSI.msk STS3ANSIMAX.msk FCC Part 68.308 Options A, B, and C Masks FCC68OPTC.msk Pre-Compliance Sonet Masks OC12SONET.msk Ieee 802.3 Masks 100BASETXSTP 100BASETXUTP Safety Document Warranty