Chapter 3 Basic Setting and Operation
Examples: Type and contents of alert mail
When the projector has an abnormality, the following alert messages are sent to the regis- tered
The following are examples of received messages.
●When internal PJ temperature is too high:
TITLE: Message from projector
Projector Model Name: model name
TCP/IP: 192.168.1.201 Projector Name: Proj05
It sends you following message.
*The Projector lamp is turned off, because internal Projector temperature is too high. Wait for the completion of cooling process and make sure the projector has been turned into Standby. Then turn the projecto on again.
If the Indicator continues flashing, check the air filter for dust accumulation.
[A]81.5 degrees fahrenheit [B] 134 degrees fahrenheit [C] 95.6 degrees fahrenheit Temperature of Sensor B is too high.
✐The network unit let users know the information which thermal sensor [A], [B] or [C] inside the projector detected the abnormal temperature risen and so the projector was turned off. Please refer to item "Power control and status check" (☞ p.42) for the location of the sensors and each temperature . Also see the owner's manual of the projector for further details.
●When internal PJ power circuit is failed:
TITLE: Message from projector
Projector Model Name: model name
TCP/IP: 192.168.1.201 Projector Name: Proj05
It sends you following message.
*The Projector lamp is turned off, because Projector power circuit is failed.
Unplug the Projector from AC outlet and ask servicing to qualified service personnel.
AV, | OK |
| ||
AV, | S5V | OK | Error information | |
PJNET, | S5V | OK | ||
| ||||
ANALOG,6V | NG |
| ||
.... | .... | .... |
|
✐The projector lamp was turned off, because the projector power circuit failed.
Unplug the projector from AC outlet and ask servicing to a qualified service personnel with the error information.
36