Motorola CLP series, CLP1040, CLP1010 manual What to do if cloning fails

Page 31

What to do if cloning fails

Note:

This cloning cable is designed to operate

The radio will emit an audible “bonk” indicating

 

only with compatible Motorola Drop-in Tray

 

Single Unit Charger. When ordering the

that the cloning process has failed. In the event

 

 

cloning cable, please refer to CLP Series

that cloning fails, try performing each of the

 

 

Cloning Cable Kit P/N HKKN4026. For

following before trying to start the cloning

 

details about accessories, refer to

process again.

 

"Accessories" Section on page 41.

 

 

1.Make sure that the radio batteries on both radios are fully charged.

2.Verify the cloning cable connection on both Single Unit Chargers.

3.Make sure that the battery is engaged properly on to the radio.

4.Make sure that there is no debris in the charging tray or on the radio contacts.

5.Verify that the source radio is in cloning mode.

6.Make sure that the radio to be cloned is turned ON.

7.Make sure that radios are both from the same type (same frequency band, same region and same transmission power).

RADIO CLONING

23

Image 31
Contents Page Disclaimer Document CopyrightsContents Radio Cloning Batteries and Chargers Safety InformationRadio Frequency Code Charts Motorola Limited Warranty Programming the Radio Through CPSComputer Software Copyrights Product Safety and RF Exposure Compliance Radio Frequency RF Exposure Safety StandardsFCC Licensing Information FCC Licensing Information Introduction Radio Overview Getting Started Install the Battery Connecting an Audio Accessory Installing and Removing the Swivel Belt Clip Holster Adjusting the VolumeTurning the Radio On and Off Talk Range Transmitting and ReceivingHOW to Step Operation with Menu SettingsSelecting a Channel Default Channel Settings for CPSFor CLP1040 multi-channel models Sending Call Tone enabled through CPSMonitoring a Channel For CLP1010 single-channel modelsBattery Life Battery and Charger FeaturesBattery Features About the Li-Ion BatteryBattery Recycling and Disposal Power Supply, Adapter and Drop-in Tray Charger Removing the Lithium-Ion Li-Ion BatteryCharging a Standalone Battery Charging the BatteryEstimated Charging Time Charging with the Drop-in Tray Single Unit Charger SUC Charging Status LEDs Charger LED IndicatorLED Checking Battery StatusBatteries Chargers Safety Information Operational Safety Guidelines Programming the Radio Programming the Radio Through CPSRadio Programming Overview Downloading the Customer Programming Software CPSFactory Default Settings Radio Cloning Cloning Radio SettingsCloning Instructions Radio Cloning What to do if cloning fails Cloning the Radio through a Multi-Unit Charger Programming the RPX through a Single Unit Charger CLP Repeater Capability Working with RPXProgramming the RPX through a Multi-Unit Charger CLP Repeater Capability Working with RPXSymptom Try this TroubleshootingCan either reduce obstructions or increase power 13 and Charger LED Indicator Section on Cannot activate VOX VOX feature might be OFF If the portable is submerged in water USE and CareCLP UHF Frequencies Radio Frequency and Code ChartsRadiofrequency CCTSS/DPL Interference Eliminator Codes DPL What Does this Warranty Cover? Motorola Limited Warranty for the United StatesProducts and Accessories Exclusions WHO is COVERED? What WE will do to Correct Warranty ProblemsHOW to Obtain Warranty Service or Other INFORMATION? SoftwareRetain Your Original Proof of Purchase Software Copyright NoticeExport LAW Assurances Patent NoticeChargers AccessoriesCarry Accessories BatteriesAccessories Page 68012000044