Nortel Networks P0886634 manual Switch SW1 should be set according to the following table

Page 16

10 Installing the DFC on systems equipped with DVCs

3.

Switch SW1 should be set according to the following table:

 

 

 

 

 

 

 

 

 

 

Position

8

7

6

5

4

3

2

1

 

 

 

 

 

 

 

 

 

 

 

State

off

on

off

off

on

on

on

on

 

 

 

 

 

 

 

 

 

 

 

 

4.

Switch SW2 should be set according to the following table:

 

 

 

 

 

 

 

 

 

 

Position

2

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

State

on

on

 

 

 

 

 

 

 

 

 

 

 

 

5.

Ensure there is a jumper on position 10 of the INTERRUPT.

 

Note: The settings in these table are the default values and should be set

 

 

properly when the board is received. Refer to Figure 2 on page 5 for

 

 

the location of the switch SW1, SW2 and the INTERRUPT jumpers.

6.

Carefully hold the DFC along the top only. Insert the card by aligning

 

between the metal groove on one side and the slot opening on the other side.

7.

Push the DFC straight in until it is snugly in place. Ensure the edge connector

 

is firmly inserted into the socket.

 

 

 

 

 

8.

Fasten the slot cover screw in the DFC slot cover.

 

 

 

Note: If there is a DVC in slot 6 of the NAM, you must connect the PEB

 

 

cable to the DFC before installation. If there is a DVC in slot 7 of the

 

 

NAM II, you must connect the PEB cable to the DFC before

 

 

installation.

 

 

 

 

 

 

 

FAX Installation Guide

P0886634 Issue 1.0

Image 16
Contents Norstar Voice Mail 4.0 FAX Installation Guide Page Contents FAX Installation Guide Regulatory information Repair facilities Introduction to Norstar Voice Mail FAX FAX overviewFAX overview Specifications DFC overviewSpecial tools Precautions Enabling the FAX softwareDVCs Installation overview Shutting down the Norstar Voice Mail systemOpening the NAM Unlocking the module doorInstalling the DFC in the NAM Locating the expansion bus slots on a NAM Switch SW1 should be set according to the following table Installing the PEB Cable NAM PEB Cable installation exampleDigital Voice Card Installing the PEB Cable Adding a Digital Voice Card after FAX is installed Installing the DFC on systems equipped with DVCs P0886634 Issue BIC Removing the BIC Keyboard/mouse backplane connector JP1 JP2 BIC connection points Re-installing the BIC in the NAM Re-installing the BIC in a NAMRe-installing the BIC in a new NAM Connecting the DFC to the BIC with the PEB Cable Connecting the BIC to the DFC in a NAM To connect the BIC to the DFC with the PEB cable Enabling the FAX software P0886634 Issue USA Comments Optional Your name Fax Company Norstar is a trademark of Northern Telecom. P0886634 Issue