20Installing the DFC on systems equipped with a BIC

2.Place the BIC on a flat surface, with the components facing up. Refer to Figure 15 on page 21.

Caution

Failure to place the BIC on a flat surface may result in serious damage to the BIC. While the BIC is out of the NAM, be careful not to slide or catch the back of the BIC, this may cause damage to the pins on the back of the board.

3.Unpack the small plastic bag from the shipping container. Make sure you have two screws and two jumpers.

4.Locate JP1 and JP2 on the BEC. JP1 and JP2 are located next to the PEB connector.

5.Remove the two jumpers from the small plastic bag. Install the two jumpers in an “open” position on the bottom pin of JP1 and JP2. For the jumper to be in the “open” position, the outside half of each jumper must not cover a pin. Refer to Figure 14 for the jumper positions.

Figure 14 BEC jumper position

JP1

JP2

Jumper Jumper

6.Unpack the BEC daughterboard from the shipping container and antistatic bag. The BIC is equipped with two posts at the bottom of the board for connection of the BEC daughterboard. Handle the BEC daughterboard by its edges at all times. Do not touch any card components. Make sure you have the two screws that came with the BEC daughterboard.

FAX Installation Guide

P0886634 Issue 1.0

Image 26
Contents Norstar Voice Mail 4.0 FAX Installation Guide Page Contents FAX Installation Guide Regulatory information Repair facilities Introduction to Norstar Voice Mail FAX FAX overviewFAX overview Special tools DFC overviewSpecifications Precautions Enabling the FAX softwareDVCs Installation overview Shutting down the Norstar Voice Mail systemOpening the NAM Unlocking the module doorInstalling the DFC in the NAM Locating the expansion bus slots on a NAM Switch SW1 should be set according to the following table Installing the PEB Cable NAM PEB Cable installation exampleDigital Voice Card Installing the PEB Cable Adding a Digital Voice Card after FAX is installed Installing the DFC on systems equipped with DVCs P0886634 Issue BIC Removing the BIC Keyboard/mouse backplane connector JP1 JP2 BIC connection points Re-installing the BIC in the NAM Re-installing the BIC in a NAMRe-installing the BIC in a new NAM Connecting the DFC to the BIC with the PEB Cable Connecting the BIC to the DFC in a NAM To connect the BIC to the DFC with the PEB cable Enabling the FAX software P0886634 Issue USA Comments Optional Your name Fax Company Norstar is a trademark of Northern Telecom. P0886634 Issue