Nortel Networks P0886634 manual Adding a Digital Voice Card after FAX is installed

Page 20

14Installing the DFC on systems equipped with DVCs

6.Close the module door.

Note: To lock the door, turn the lock 90° clockwise until the screwdriver slot is horizontal.

7.Plug the power cord into the AC outlet.

Adding a Digital Voice Card after FAX is installed

After you have installed the FAX option on the NAM, the installation of another DVC requires a few extra steps. These extra steps are required to remove PEB terminators and install the PEB cable.

To install a DVC:

1.Warn customers that Norstar Voice Mail will be out of service while you are installing the expansion card.

2.Shutdown the NAM. For more information, refer to "Shutting down the Norstar Voice Mail system" on page 6.

3.Remove the NAM power cord from the AC outlet.

4.Ground yourself by attaching one end of the grounding strap to your wrist and the other end to a grounded metal surface.

5.Open the NAM door and remove the front cover. Refer to "Opening the NAM" on page 7.

6.Set the switches and jumpers on the DVC you are adding. Settings for the switches and jumpers are listed in the Norstar Applications Module II Installation and Maintenance Manual.

7.Remove the XRN1 and XRN2 terminators from the DVC you are installing.

Note: Keep the PEB terminators in a safe place. If the DFC is removed, the terminator plugs must be re-installed on the DVCs.

8.Disconnect the PEB cable from the DVCs already installed in the NAM.

9.Remove the slot cover screw and the metal slot cover from the slot you are adding the new DVC to. DVC slot assignment is listed in the

Norstar Applications Module II Installation and Maintenance Manual.

10.Insert the new DVC into the appropriate slot.

11.Connect the PEB cable to each DVC in the NAM.

FAX Installation Guide

P0886634 Issue 1.0

Image 20
Contents Norstar Voice Mail 4.0 FAX Installation Guide Page Contents FAX Installation Guide Regulatory information Repair facilities Introduction to Norstar Voice Mail FAX FAX overviewFAX overview Special tools DFC overviewSpecifications Precautions Enabling the FAX softwareDVCs Installation overview Shutting down the Norstar Voice Mail systemOpening the NAM Unlocking the module doorInstalling the DFC in the NAM Locating the expansion bus slots on a NAM Switch SW1 should be set according to the following table Installing the PEB Cable NAM PEB Cable installation exampleDigital Voice Card Installing the PEB Cable Adding a Digital Voice Card after FAX is installed Installing the DFC on systems equipped with DVCs P0886634 Issue BIC Removing the BIC Keyboard/mouse backplane connector JP1 JP2 BIC connection points Re-installing the BIC in the NAM Re-installing the BIC in a NAMRe-installing the BIC in a new NAM Connecting the DFC to the BIC with the PEB Cable Connecting the BIC to the DFC in a NAM To connect the BIC to the DFC with the PEB cable Enabling the FAX software P0886634 Issue USA Comments Optional Your name Fax Company Norstar is a trademark of Northern Telecom. P0886634 Issue